{"title":"工业厂房空调用空气冷却气体吸收系统参数的确定","authors":"A. F. Burkov, I. V. Zavchenko, V. Sokolova","doi":"10.1109/FAREASTCON.2018.8602551","DOIUrl":null,"url":null,"abstract":"The goal of this research is to estimate prospects of using natural gas absorption system as a conditioning system for industrial premises in summer time. In this paper we explored and validated the main tendencies in organization if microclimate at the industrial enterprises. The number of problems related with integration of absorption cooling machines to the industrial facility was listed. It was proposed to examine the issue of application of local low power absorption system for conditioning. In this work we carried out thermal design of absorption system. Based of calculation results we carried out heat engineering calculations of closed cooling tower, which satisfies the requirements for heat diversion during exploitation of this absorption system. We carried out economic design and based on results analysis we draw a conclusion about practicability of implementation of proposed solution to the industrial facilities.","PeriodicalId":177690,"journal":{"name":"2018 International Multi-Conference on Industrial Engineering and Modern Technologies (FarEastCon)","volume":"2 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2018-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":"{\"title\":\"Determination of Parameters of the Gas Absorption System with Air Cooling for Conditioning of Industrial Premise\",\"authors\":\"A. F. Burkov, I. V. Zavchenko, V. Sokolova\",\"doi\":\"10.1109/FAREASTCON.2018.8602551\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The goal of this research is to estimate prospects of using natural gas absorption system as a conditioning system for industrial premises in summer time. In this paper we explored and validated the main tendencies in organization if microclimate at the industrial enterprises. The number of problems related with integration of absorption cooling machines to the industrial facility was listed. It was proposed to examine the issue of application of local low power absorption system for conditioning. In this work we carried out thermal design of absorption system. Based of calculation results we carried out heat engineering calculations of closed cooling tower, which satisfies the requirements for heat diversion during exploitation of this absorption system. We carried out economic design and based on results analysis we draw a conclusion about practicability of implementation of proposed solution to the industrial facilities.\",\"PeriodicalId\":177690,\"journal\":{\"name\":\"2018 International Multi-Conference on Industrial Engineering and Modern Technologies (FarEastCon)\",\"volume\":\"2 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2018-10-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"3\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2018 International Multi-Conference on Industrial Engineering and Modern Technologies (FarEastCon)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/FAREASTCON.2018.8602551\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2018 International Multi-Conference on Industrial Engineering and Modern Technologies (FarEastCon)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/FAREASTCON.2018.8602551","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Determination of Parameters of the Gas Absorption System with Air Cooling for Conditioning of Industrial Premise
The goal of this research is to estimate prospects of using natural gas absorption system as a conditioning system for industrial premises in summer time. In this paper we explored and validated the main tendencies in organization if microclimate at the industrial enterprises. The number of problems related with integration of absorption cooling machines to the industrial facility was listed. It was proposed to examine the issue of application of local low power absorption system for conditioning. In this work we carried out thermal design of absorption system. Based of calculation results we carried out heat engineering calculations of closed cooling tower, which satisfies the requirements for heat diversion during exploitation of this absorption system. We carried out economic design and based on results analysis we draw a conclusion about practicability of implementation of proposed solution to the industrial facilities.