Jiangtao Quan, Q. Guo, Ling Ruan, Ruiji Yu, Y. Luo, Zhicheng Wang, Fanrong Wei, Jinwen Sun, Xiangning Lin
{"title":"宜昌电网220 kV变电直流偏置中性点接线方式优化配置","authors":"Jiangtao Quan, Q. Guo, Ling Ruan, Ruiji Yu, Y. Luo, Zhicheng Wang, Fanrong Wei, Jinwen Sun, Xiangning Lin","doi":"10.1109/RTUCON.2014.6998202","DOIUrl":null,"url":null,"abstract":"The occurrence of DC Bias will affect the normal operation of power transformer, thus DC bias withstand capability of transformer is a prerequisite for stable operation of power system. In this paper, the DC current distribution model of transformer neutral point in Yichang area is established. Meanwhile, according to the transformer noise limit, the maximum current which is allowable to flow through transformer neutral point is determined. On this basis, an optimization of neutral point connection mode configuration is proposed to inhibit DC bias. Since the change of zero sequence impedance, at last we give sensitivity verification of zero sequence current protection base on the RelayCAC model of Yichang power grid. Simulation results show that the sensitivity meet the requirements and verify the effectiveness of the proposed method.","PeriodicalId":259790,"journal":{"name":"2014 55th International Scientific Conference on Power and Electrical Engineering of Riga Technical University (RTUCON)","volume":"2 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2014-12-29","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":"{\"title\":\"Optimized neutral point connection mode configuration against DC Bias of 220 kV power transformation in Yichang power grid\",\"authors\":\"Jiangtao Quan, Q. Guo, Ling Ruan, Ruiji Yu, Y. Luo, Zhicheng Wang, Fanrong Wei, Jinwen Sun, Xiangning Lin\",\"doi\":\"10.1109/RTUCON.2014.6998202\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The occurrence of DC Bias will affect the normal operation of power transformer, thus DC bias withstand capability of transformer is a prerequisite for stable operation of power system. In this paper, the DC current distribution model of transformer neutral point in Yichang area is established. Meanwhile, according to the transformer noise limit, the maximum current which is allowable to flow through transformer neutral point is determined. On this basis, an optimization of neutral point connection mode configuration is proposed to inhibit DC bias. Since the change of zero sequence impedance, at last we give sensitivity verification of zero sequence current protection base on the RelayCAC model of Yichang power grid. Simulation results show that the sensitivity meet the requirements and verify the effectiveness of the proposed method.\",\"PeriodicalId\":259790,\"journal\":{\"name\":\"2014 55th International Scientific Conference on Power and Electrical Engineering of Riga Technical University (RTUCON)\",\"volume\":\"2 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2014-12-29\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2014 55th International Scientific Conference on Power and Electrical Engineering of Riga Technical University (RTUCON)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/RTUCON.2014.6998202\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2014 55th International Scientific Conference on Power and Electrical Engineering of Riga Technical University (RTUCON)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/RTUCON.2014.6998202","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Optimized neutral point connection mode configuration against DC Bias of 220 kV power transformation in Yichang power grid
The occurrence of DC Bias will affect the normal operation of power transformer, thus DC bias withstand capability of transformer is a prerequisite for stable operation of power system. In this paper, the DC current distribution model of transformer neutral point in Yichang area is established. Meanwhile, according to the transformer noise limit, the maximum current which is allowable to flow through transformer neutral point is determined. On this basis, an optimization of neutral point connection mode configuration is proposed to inhibit DC bias. Since the change of zero sequence impedance, at last we give sensitivity verification of zero sequence current protection base on the RelayCAC model of Yichang power grid. Simulation results show that the sensitivity meet the requirements and verify the effectiveness of the proposed method.