用于体温监测的接触式/非接触式传感器网格

M. Özgören, M. Sakar, A. Öniz
{"title":"用于体温监测的接触式/非接触式传感器网格","authors":"M. Özgören, M. Sakar, A. Öniz","doi":"10.1109/BIYOMUT.2010.5479808","DOIUrl":null,"url":null,"abstract":"In this study, a low-cost data acquisition (DAQ) system has been developed to measure the body temperature from multiple points using a sensor network approach. This system collects raw data with long-term recording and stores for further analysis. Contact and non-contact types of temperature sensors were used. The system was especially designed for measuring from head during electroencephalography (EEG) recordings. The system can record data during the normal daily activities because of its portability. Observing body thermo-regulation in a time period of 24 to 36 hours and finding the correlation with the ambient temperature requires very long time physiological recording. Thus, it has been made possible to record temperature everywhere and in day or night time without limiting the mobility. Using different type of temperature sensors and measuring the ambient temperature allows determining the temperature differences and the thermal response of body separately. As a result, a low cost, compact, portable, and durable measuring system with using two types of temperature sensors has been designed for considering easy and reliable measurements.","PeriodicalId":180275,"journal":{"name":"2010 15th National Biomedical Engineering Meeting","volume":"176 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2010-04-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":"{\"title\":\"Contact/non-contact sensor mesh for body temperature monitoring\",\"authors\":\"M. Özgören, M. Sakar, A. Öniz\",\"doi\":\"10.1109/BIYOMUT.2010.5479808\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"In this study, a low-cost data acquisition (DAQ) system has been developed to measure the body temperature from multiple points using a sensor network approach. This system collects raw data with long-term recording and stores for further analysis. Contact and non-contact types of temperature sensors were used. The system was especially designed for measuring from head during electroencephalography (EEG) recordings. The system can record data during the normal daily activities because of its portability. Observing body thermo-regulation in a time period of 24 to 36 hours and finding the correlation with the ambient temperature requires very long time physiological recording. Thus, it has been made possible to record temperature everywhere and in day or night time without limiting the mobility. Using different type of temperature sensors and measuring the ambient temperature allows determining the temperature differences and the thermal response of body separately. As a result, a low cost, compact, portable, and durable measuring system with using two types of temperature sensors has been designed for considering easy and reliable measurements.\",\"PeriodicalId\":180275,\"journal\":{\"name\":\"2010 15th National Biomedical Engineering Meeting\",\"volume\":\"176 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2010-04-21\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"3\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2010 15th National Biomedical Engineering Meeting\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/BIYOMUT.2010.5479808\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2010 15th National Biomedical Engineering Meeting","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/BIYOMUT.2010.5479808","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 3

摘要

在这项研究中,开发了一种低成本的数据采集(DAQ)系统,使用传感器网络方法从多个点测量体温。该系统收集原始数据,并进行长期记录和存储,以供进一步分析。采用接触式和非接触式温度传感器。该系统专为脑电图(EEG)记录时的头部测量而设计。该系统具有便携性,可以记录日常活动中的数据。观察24 ~ 36小时的体温调节,并找出与环境温度的关系,需要很长时间的生理记录。因此,它已经成为可能记录温度在任何地方,在白天或晚上的时间,而不限制机动性。使用不同类型的温度传感器和测量环境温度,可以分别确定温度差异和身体的热响应。因此,考虑到测量的简单和可靠,设计了一种低成本、紧凑、便携和耐用的测量系统,使用两种类型的温度传感器。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Contact/non-contact sensor mesh for body temperature monitoring
In this study, a low-cost data acquisition (DAQ) system has been developed to measure the body temperature from multiple points using a sensor network approach. This system collects raw data with long-term recording and stores for further analysis. Contact and non-contact types of temperature sensors were used. The system was especially designed for measuring from head during electroencephalography (EEG) recordings. The system can record data during the normal daily activities because of its portability. Observing body thermo-regulation in a time period of 24 to 36 hours and finding the correlation with the ambient temperature requires very long time physiological recording. Thus, it has been made possible to record temperature everywhere and in day or night time without limiting the mobility. Using different type of temperature sensors and measuring the ambient temperature allows determining the temperature differences and the thermal response of body separately. As a result, a low cost, compact, portable, and durable measuring system with using two types of temperature sensors has been designed for considering easy and reliable measurements.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Effect of channel noise on spike propagation in myelinated axons The differences of MR spectroscopic imaging and MR diffusion weighted imaging parameters in different subtypes of grade 3 gliomas Chronic recordings from rat motor cortex for developing neural prostheses Classification of ECG Arrythmia beats with Artificial Neural Networks Modifying medical textiles with antibacterial and friction resistance abilities by an alternative nanotextile technology called ion implantation technique
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1