Young Roc Kim, Byung Hun Ra, J. S. Moon, Y. Shin, Seok Ki Kim
{"title":"200kW并网光伏逆变器的研制","authors":"Young Roc Kim, Byung Hun Ra, J. S. Moon, Y. Shin, Seok Ki Kim","doi":"10.1109/ICPE.2007.4692429","DOIUrl":null,"url":null,"abstract":"This paper presents development of 200 kW grid connected PV inverter. 200 kW Grid connected PV inverter has the utility frequency transformer for the galvanic isolation between DC and AC , and its output is 3-phase 3-wire 60 Hz, 380 V. P&O algorithm is used for the maximum power point tracking (MPPT) and the active frequency drift scheme for the anti islanding protection. The inverter is controlled by 32 bit DSP. This paper explain the performance and test result of utility interface, anti-islanding, efficiency and THD of 200 kW grid connected PV inverter.","PeriodicalId":211729,"journal":{"name":"2007 International Conference on Electrical Machines and Systems (ICEMS)","volume":"1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2007-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Development of 200kW grid-connected photovoltaic inverter\",\"authors\":\"Young Roc Kim, Byung Hun Ra, J. S. Moon, Y. Shin, Seok Ki Kim\",\"doi\":\"10.1109/ICPE.2007.4692429\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper presents development of 200 kW grid connected PV inverter. 200 kW Grid connected PV inverter has the utility frequency transformer for the galvanic isolation between DC and AC , and its output is 3-phase 3-wire 60 Hz, 380 V. P&O algorithm is used for the maximum power point tracking (MPPT) and the active frequency drift scheme for the anti islanding protection. The inverter is controlled by 32 bit DSP. This paper explain the performance and test result of utility interface, anti-islanding, efficiency and THD of 200 kW grid connected PV inverter.\",\"PeriodicalId\":211729,\"journal\":{\"name\":\"2007 International Conference on Electrical Machines and Systems (ICEMS)\",\"volume\":\"1 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2007-10-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2007 International Conference on Electrical Machines and Systems (ICEMS)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICPE.2007.4692429\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2007 International Conference on Electrical Machines and Systems (ICEMS)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICPE.2007.4692429","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Development of 200kW grid-connected photovoltaic inverter
This paper presents development of 200 kW grid connected PV inverter. 200 kW Grid connected PV inverter has the utility frequency transformer for the galvanic isolation between DC and AC , and its output is 3-phase 3-wire 60 Hz, 380 V. P&O algorithm is used for the maximum power point tracking (MPPT) and the active frequency drift scheme for the anti islanding protection. The inverter is controlled by 32 bit DSP. This paper explain the performance and test result of utility interface, anti-islanding, efficiency and THD of 200 kW grid connected PV inverter.