{"title":"侧光器:一种新型无死区故障光缆距离测量系统","authors":"A. Paolella","doi":"10.1109/AVFOP.2006.1707486","DOIUrl":null,"url":null,"abstract":"We have shown a method of locating faults in fiber using a new Sidelighter module that easily connects to popular microwave analyzers. The Sidelighter can be used in the field as it is compact and battery operated. Using the Sidelighter allow users to test RF and optical cables in one system. We have achieved 10 cm measurement resolution and can located failures in fibers at distances of up to 1 Km","PeriodicalId":175517,"journal":{"name":"IEEE Conference Avionics Fiber-Optics and Photonics, 2006.","volume":"55 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2006-10-09","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"The Sidelighter: A New Dead-Zone Free Distance to Fault Fiber Optic Cable Measurement System\",\"authors\":\"A. Paolella\",\"doi\":\"10.1109/AVFOP.2006.1707486\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"We have shown a method of locating faults in fiber using a new Sidelighter module that easily connects to popular microwave analyzers. The Sidelighter can be used in the field as it is compact and battery operated. Using the Sidelighter allow users to test RF and optical cables in one system. We have achieved 10 cm measurement resolution and can located failures in fibers at distances of up to 1 Km\",\"PeriodicalId\":175517,\"journal\":{\"name\":\"IEEE Conference Avionics Fiber-Optics and Photonics, 2006.\",\"volume\":\"55 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2006-10-09\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"IEEE Conference Avionics Fiber-Optics and Photonics, 2006.\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/AVFOP.2006.1707486\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"IEEE Conference Avionics Fiber-Optics and Photonics, 2006.","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/AVFOP.2006.1707486","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
The Sidelighter: A New Dead-Zone Free Distance to Fault Fiber Optic Cable Measurement System
We have shown a method of locating faults in fiber using a new Sidelighter module that easily connects to popular microwave analyzers. The Sidelighter can be used in the field as it is compact and battery operated. Using the Sidelighter allow users to test RF and optical cables in one system. We have achieved 10 cm measurement resolution and can located failures in fibers at distances of up to 1 Km