用于大型强子对撞机电子元件测试的A /sup 252/Cf中子辐照器

J. De la Cova, W. Gilbert, M. Graham, J. Kilgore, I. Kronkvist, R. Flusack, R. Schwienhorst, J. Sielaff, D. Sievers, T. Vidnovic
{"title":"用于大型强子对撞机电子元件测试的A /sup 252/Cf中子辐照器","authors":"J. De la Cova, W. Gilbert, M. Graham, J. Kilgore, I. Kronkvist, R. Flusack, R. Schwienhorst, J. Sielaff, D. Sievers, T. Vidnovic","doi":"10.1109/NSSMIC.2001.1009649","DOIUrl":null,"url":null,"abstract":"The radiation levels inside the experiments at the LHC will be very high. To ensure that all the electronics components used in the detectors will survive for the life the experiments, they will all be thoroughly tested for radiation hardness with neutrons and gammas. The CMS Electromagnetic Calorimeter has a dedicated neutron irradiator at the University of Minnesota to perform neutron irradiation of all electronic components that will be mounted on the detector. The irradiator uses 11.5 mg of /sup 252/Cf for the source, with a neutron flux of /spl ap/ 9.5 /spl times/ 10/sup 13/ neutrons/h. In this paper the design, construction, and operations of the Californium Neutron Irradiator will be described.","PeriodicalId":159123,"journal":{"name":"2001 IEEE Nuclear Science Symposium Conference Record (Cat. No.01CH37310)","volume":"46 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2001-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"A /sup 252/Cf neutron irradiator for testing electronic components for the Large Hadron Collider\",\"authors\":\"J. De la Cova, W. Gilbert, M. Graham, J. Kilgore, I. Kronkvist, R. Flusack, R. Schwienhorst, J. Sielaff, D. Sievers, T. Vidnovic\",\"doi\":\"10.1109/NSSMIC.2001.1009649\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The radiation levels inside the experiments at the LHC will be very high. To ensure that all the electronics components used in the detectors will survive for the life the experiments, they will all be thoroughly tested for radiation hardness with neutrons and gammas. The CMS Electromagnetic Calorimeter has a dedicated neutron irradiator at the University of Minnesota to perform neutron irradiation of all electronic components that will be mounted on the detector. The irradiator uses 11.5 mg of /sup 252/Cf for the source, with a neutron flux of /spl ap/ 9.5 /spl times/ 10/sup 13/ neutrons/h. In this paper the design, construction, and operations of the Californium Neutron Irradiator will be described.\",\"PeriodicalId\":159123,\"journal\":{\"name\":\"2001 IEEE Nuclear Science Symposium Conference Record (Cat. No.01CH37310)\",\"volume\":\"46 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2001-12-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2001 IEEE Nuclear Science Symposium Conference Record (Cat. No.01CH37310)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/NSSMIC.2001.1009649\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2001 IEEE Nuclear Science Symposium Conference Record (Cat. No.01CH37310)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/NSSMIC.2001.1009649","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

在大型强子对撞机的实验中,辐射水平将非常高。为了确保探测器中使用的所有电子元件在实验期间都能存活下来,它们都将经过中子和伽马辐射硬度的彻底测试。CMS电磁量热计在明尼苏达大学有一个专用的中子辐照器,用于对安装在探测器上的所有电子元件进行中子辐照。辐照器使用11.5 mg /sup 252/Cf作为源,中子通量为/spl / 9.5 /spl倍/ 10/sup 13/中子/h。本文将介绍加利福尼亚中子辐照器的设计、建造和运行情况。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
A /sup 252/Cf neutron irradiator for testing electronic components for the Large Hadron Collider
The radiation levels inside the experiments at the LHC will be very high. To ensure that all the electronics components used in the detectors will survive for the life the experiments, they will all be thoroughly tested for radiation hardness with neutrons and gammas. The CMS Electromagnetic Calorimeter has a dedicated neutron irradiator at the University of Minnesota to perform neutron irradiation of all electronic components that will be mounted on the detector. The irradiator uses 11.5 mg of /sup 252/Cf for the source, with a neutron flux of /spl ap/ 9.5 /spl times/ 10/sup 13/ neutrons/h. In this paper the design, construction, and operations of the Californium Neutron Irradiator will be described.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Comparison of IEC and IEEE standards for computer-based control systems important to safety Helicity-correlated systematics for SLAC Experiment E158 Achievements of the ASTRO-E Hard X-ray Detector development Inexpensive position sensitive detector block for 40 mm diameter PMT using quadrant sharing configuration A /sup 252/Cf neutron irradiator for testing electronic components for the Large Hadron Collider
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1