{"title":"采用变频和占空控制的光电功率增量辅助增量电导最大功率点跟踪","authors":"G. Hsieh, Cheng-Yuan Tsai, Hung-I Hsieh","doi":"10.1109/PEDG.2012.6254055","DOIUrl":null,"url":null,"abstract":"This paper presents a smart photovoltaic (PV) power-increment-aided incremental-conductance MPPT (PI-INC MPPT) using either variable-frequency constant-duty control (VFCD) or constant-frequency variable-duty control (CFVD). The tracking of PI-INC MPPT with reference to a threshold tracking zone (THZ) is implemented by a two-step approach, a power-increment (PI) coarse-tracking along Ppv-Vpv curve and an incremental-conductance (INC) fine-tracking along Ipv-Vpv curve. An ambiguous detection using INC MPPT, in the flat-and-low conductance region of Ipv-Vpv curve, will not be arisen by using the PI coarse-tracking that enriches the PI-INC MPPT fast tracking along Ppv-Vpv curve with obvious detection against the potential tracking delay. Modeling and analysis of two typical PV power converters, using VFCD and CFVD controls, which implement the tracking of the PI-INC MPPT, are respectively addressed. The effectiveness of the tracking behavior of PI-INC MPPT by the two power converters in comparison with that using conventional INC-MPPT is assessed through the experimental tests.","PeriodicalId":146438,"journal":{"name":"2012 3rd IEEE International Symposium on Power Electronics for Distributed Generation Systems (PEDG)","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2012-06-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"14","resultStr":"{\"title\":\"Photovoltaic power-increment-aided incremental-conductance maximum power point tracking using variable frequency and duty controls\",\"authors\":\"G. Hsieh, Cheng-Yuan Tsai, Hung-I Hsieh\",\"doi\":\"10.1109/PEDG.2012.6254055\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper presents a smart photovoltaic (PV) power-increment-aided incremental-conductance MPPT (PI-INC MPPT) using either variable-frequency constant-duty control (VFCD) or constant-frequency variable-duty control (CFVD). The tracking of PI-INC MPPT with reference to a threshold tracking zone (THZ) is implemented by a two-step approach, a power-increment (PI) coarse-tracking along Ppv-Vpv curve and an incremental-conductance (INC) fine-tracking along Ipv-Vpv curve. An ambiguous detection using INC MPPT, in the flat-and-low conductance region of Ipv-Vpv curve, will not be arisen by using the PI coarse-tracking that enriches the PI-INC MPPT fast tracking along Ppv-Vpv curve with obvious detection against the potential tracking delay. Modeling and analysis of two typical PV power converters, using VFCD and CFVD controls, which implement the tracking of the PI-INC MPPT, are respectively addressed. The effectiveness of the tracking behavior of PI-INC MPPT by the two power converters in comparison with that using conventional INC-MPPT is assessed through the experimental tests.\",\"PeriodicalId\":146438,\"journal\":{\"name\":\"2012 3rd IEEE International Symposium on Power Electronics for Distributed Generation Systems (PEDG)\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2012-06-25\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"14\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2012 3rd IEEE International Symposium on Power Electronics for Distributed Generation Systems (PEDG)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/PEDG.2012.6254055\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2012 3rd IEEE International Symposium on Power Electronics for Distributed Generation Systems (PEDG)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/PEDG.2012.6254055","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Photovoltaic power-increment-aided incremental-conductance maximum power point tracking using variable frequency and duty controls
This paper presents a smart photovoltaic (PV) power-increment-aided incremental-conductance MPPT (PI-INC MPPT) using either variable-frequency constant-duty control (VFCD) or constant-frequency variable-duty control (CFVD). The tracking of PI-INC MPPT with reference to a threshold tracking zone (THZ) is implemented by a two-step approach, a power-increment (PI) coarse-tracking along Ppv-Vpv curve and an incremental-conductance (INC) fine-tracking along Ipv-Vpv curve. An ambiguous detection using INC MPPT, in the flat-and-low conductance region of Ipv-Vpv curve, will not be arisen by using the PI coarse-tracking that enriches the PI-INC MPPT fast tracking along Ppv-Vpv curve with obvious detection against the potential tracking delay. Modeling and analysis of two typical PV power converters, using VFCD and CFVD controls, which implement the tracking of the PI-INC MPPT, are respectively addressed. The effectiveness of the tracking behavior of PI-INC MPPT by the two power converters in comparison with that using conventional INC-MPPT is assessed through the experimental tests.