一种基于颅骨减压术后特征参数估计头皮皮瓣表面积的方法

Lian Gao, Ninghui Zhao, Jinxi Zhao, Qinhu Zhang, Lan-juan Liu, Yufeng Zhang, He Sun, Xinling Shi
{"title":"一种基于颅骨减压术后特征参数估计头皮皮瓣表面积的方法","authors":"Lian Gao, Ninghui Zhao, Jinxi Zhao, Qinhu Zhang, Lan-juan Liu, Yufeng Zhang, He Sun, Xinling Shi","doi":"10.1109/ISBB.2014.6820949","DOIUrl":null,"url":null,"abstract":"An approach for the estimation of the surface area of scalp flap after decompressive craniectomy is presented in this paper to avoid the complications after cranioplasty since the area of the implanted prosthesis such as the titanium alloy is large than the surface area of the scalp flap. The estimation is based on the simulation model of skull with the characteristic parameters obtained from clinical statistics by using Mimics and the integration method to calculate the surface area of the scalp flap where the bone flap was removed for the relief of intractable intracranial hypertension in patients with severe traumatic brain injury by considering the sunken degree of the brain and scalp flap. In order to evaluate the performance of the proposed method, the comparison of the results obtained from the clinical statistical and simulation study is carried out. The results indicate that the computed value of the scalp flap area obtained from the simulation is consistent quite well with the results of clinical statistics.","PeriodicalId":265886,"journal":{"name":"2014 IEEE International Symposium on Bioelectronics and Bioinformatics (IEEE ISBB 2014)","volume":"65 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2014-04-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"An approach for estimation of the surface area of scalp flap based on the characteristic parameters after decompressive craniectomy\",\"authors\":\"Lian Gao, Ninghui Zhao, Jinxi Zhao, Qinhu Zhang, Lan-juan Liu, Yufeng Zhang, He Sun, Xinling Shi\",\"doi\":\"10.1109/ISBB.2014.6820949\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"An approach for the estimation of the surface area of scalp flap after decompressive craniectomy is presented in this paper to avoid the complications after cranioplasty since the area of the implanted prosthesis such as the titanium alloy is large than the surface area of the scalp flap. The estimation is based on the simulation model of skull with the characteristic parameters obtained from clinical statistics by using Mimics and the integration method to calculate the surface area of the scalp flap where the bone flap was removed for the relief of intractable intracranial hypertension in patients with severe traumatic brain injury by considering the sunken degree of the brain and scalp flap. In order to evaluate the performance of the proposed method, the comparison of the results obtained from the clinical statistical and simulation study is carried out. The results indicate that the computed value of the scalp flap area obtained from the simulation is consistent quite well with the results of clinical statistics.\",\"PeriodicalId\":265886,\"journal\":{\"name\":\"2014 IEEE International Symposium on Bioelectronics and Bioinformatics (IEEE ISBB 2014)\",\"volume\":\"65 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2014-04-11\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2014 IEEE International Symposium on Bioelectronics and Bioinformatics (IEEE ISBB 2014)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ISBB.2014.6820949\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2014 IEEE International Symposium on Bioelectronics and Bioinformatics (IEEE ISBB 2014)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ISBB.2014.6820949","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

摘要

为了避免颅骨成形术后由于植入的钛合金等假体面积大于头皮瓣表面积而导致的并发症,本文提出了一种估计颅骨减压切除术后头皮瓣表面积的方法。该估计是基于模拟颅骨模型,结合临床统计得到的特征参数,利用Mimics和积分法,考虑脑和头皮瓣的凹陷程度,计算重型颅脑损伤患者解除顽固性颅内高压时取骨瓣处的头皮瓣表面积。为了评价所提方法的性能,将临床统计和仿真研究结果进行了比较。结果表明,模拟得到的头皮皮瓣面积计算值与临床统计结果吻合较好。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
An approach for estimation of the surface area of scalp flap based on the characteristic parameters after decompressive craniectomy
An approach for the estimation of the surface area of scalp flap after decompressive craniectomy is presented in this paper to avoid the complications after cranioplasty since the area of the implanted prosthesis such as the titanium alloy is large than the surface area of the scalp flap. The estimation is based on the simulation model of skull with the characteristic parameters obtained from clinical statistics by using Mimics and the integration method to calculate the surface area of the scalp flap where the bone flap was removed for the relief of intractable intracranial hypertension in patients with severe traumatic brain injury by considering the sunken degree of the brain and scalp flap. In order to evaluate the performance of the proposed method, the comparison of the results obtained from the clinical statistical and simulation study is carried out. The results indicate that the computed value of the scalp flap area obtained from the simulation is consistent quite well with the results of clinical statistics.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Stereoscopic laparoscopy using depth information from 3D model Analysis of the multiple ultrasound echoes for measurement of cortical bone thickness Smart cane: Instrumentation of a quad cane with audio-feedback monitoring system for partial weight-bearing support A low power high CMRR CMOS instrumentation amplifier for Bio-impedance Spectroscopy A novel approach for ECG data compression in healthcare monitoring system
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1