考虑动负荷的网络频率响应新研究

H. Nouri
{"title":"考虑动负荷的网络频率响应新研究","authors":"H. Nouri","doi":"10.11591/IJAPE.V8.I3.PP%P","DOIUrl":null,"url":null,"abstract":"The dynamic model construction of transmission network components that include generator buses, load buses and power branches, within MATLAB-Simulink environment is presented. The degree of frequency deviation of buses when the power of motor loads and static loads vary, is studied. Furthermore, the influence of motor loads with different inertia constants are considered in the control technique of load frequency using a PID controller. The results show that the frequency oscillation of the dynamic load is greater than the frequency oscillation of static load. Also the speed of frequency control of the dynamic load is greater than the speed of the frequency control of the static load and the inertia constants of the dynamic load has significant influence on the frequency control characteristics.","PeriodicalId":280098,"journal":{"name":"International Journal of Applied Power Engineering","volume":"76 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2019-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"New studies on network frequency responses considering dynamic loads\",\"authors\":\"H. Nouri\",\"doi\":\"10.11591/IJAPE.V8.I3.PP%P\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The dynamic model construction of transmission network components that include generator buses, load buses and power branches, within MATLAB-Simulink environment is presented. The degree of frequency deviation of buses when the power of motor loads and static loads vary, is studied. Furthermore, the influence of motor loads with different inertia constants are considered in the control technique of load frequency using a PID controller. The results show that the frequency oscillation of the dynamic load is greater than the frequency oscillation of static load. Also the speed of frequency control of the dynamic load is greater than the speed of the frequency control of the static load and the inertia constants of the dynamic load has significant influence on the frequency control characteristics.\",\"PeriodicalId\":280098,\"journal\":{\"name\":\"International Journal of Applied Power Engineering\",\"volume\":\"76 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2019-12-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"International Journal of Applied Power Engineering\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.11591/IJAPE.V8.I3.PP%P\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal of Applied Power Engineering","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.11591/IJAPE.V8.I3.PP%P","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

摘要

介绍了在MATLAB-Simulink环境下,对包括发电母线、负荷母线和电力支路在内的输电网部件进行动态建模的方法。研究了电机负载和静负载功率变化时母线频率偏差的程度。此外,在采用PID控制的负载频率控制技术中,考虑了不同惯量的电机负载的影响。结果表明,动载荷的频率振荡大于静载荷的频率振荡。动负载的频率控制速度大于静负载的频率控制速度,动负载的惯性常数对频率控制特性有显著影响。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
New studies on network frequency responses considering dynamic loads
The dynamic model construction of transmission network components that include generator buses, load buses and power branches, within MATLAB-Simulink environment is presented. The degree of frequency deviation of buses when the power of motor loads and static loads vary, is studied. Furthermore, the influence of motor loads with different inertia constants are considered in the control technique of load frequency using a PID controller. The results show that the frequency oscillation of the dynamic load is greater than the frequency oscillation of static load. Also the speed of frequency control of the dynamic load is greater than the speed of the frequency control of the static load and the inertia constants of the dynamic load has significant influence on the frequency control characteristics.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Squirrel Cage Induction Motor Predictive Direct Torque Control based on multi-step delay compensation Power quality improvement using a shunt active power filter based on an cascaded H-bridge eleven level inverter with predictive current control Calculation and measurement of ampacity for class 5 flexible aluminum cable at 110 °C Problems and analysis directions in smart grid technology and their potential solutions Performance enhancement of shunt active power filter using soft computing techniques
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1