Z. Hamid, N. A. Salim, Nur Atiqah Abdul Rahman, Siti Aisyah Al-Shafiqah Aminuddin
{"title":"通过优化UPFC布局降低输电系统的电压水平和实际功率损耗","authors":"Z. Hamid, N. A. Salim, Nur Atiqah Abdul Rahman, Siti Aisyah Al-Shafiqah Aminuddin","doi":"10.1109/ICPEA53519.2022.9744672","DOIUrl":null,"url":null,"abstract":"In a large scale power network, maintaining the magnitude of bus voltages within nominal operating level at all buses is a vital requirement. With such condition, the system will have an optimal transmission line performance with minimum power losses and no overloading issue. To achieve this, the power flow along transmission line ought to be properly controlled using special devices like the Unified Power Flow Controller (UPFC) - a multipurpose device which can control power flow by modifying the voltage magnitude, phase angle and impedance of transmission lines. Hence, this paper proposes a technique for mitigating voltage level and real power losses in transmission system using optimal placement of UPFC and Evolutionary Programming (EP). The implementation of the proposed technique involved IEEE 14-bus reliability test system. Experiment and analysis has justified the capability of EP-based UPFC placement for voltage stability improvement and power loss minimization as well.","PeriodicalId":371063,"journal":{"name":"2022 IEEE International Conference in Power Engineering Application (ICPEA)","volume":"24 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2022-03-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Mitigation of Voltage Level and Real Power Loss in Transmission System via Optimal UPFC Placement\",\"authors\":\"Z. Hamid, N. A. Salim, Nur Atiqah Abdul Rahman, Siti Aisyah Al-Shafiqah Aminuddin\",\"doi\":\"10.1109/ICPEA53519.2022.9744672\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"In a large scale power network, maintaining the magnitude of bus voltages within nominal operating level at all buses is a vital requirement. With such condition, the system will have an optimal transmission line performance with minimum power losses and no overloading issue. To achieve this, the power flow along transmission line ought to be properly controlled using special devices like the Unified Power Flow Controller (UPFC) - a multipurpose device which can control power flow by modifying the voltage magnitude, phase angle and impedance of transmission lines. Hence, this paper proposes a technique for mitigating voltage level and real power losses in transmission system using optimal placement of UPFC and Evolutionary Programming (EP). The implementation of the proposed technique involved IEEE 14-bus reliability test system. Experiment and analysis has justified the capability of EP-based UPFC placement for voltage stability improvement and power loss minimization as well.\",\"PeriodicalId\":371063,\"journal\":{\"name\":\"2022 IEEE International Conference in Power Engineering Application (ICPEA)\",\"volume\":\"24 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2022-03-07\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2022 IEEE International Conference in Power Engineering Application (ICPEA)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICPEA53519.2022.9744672\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2022 IEEE International Conference in Power Engineering Application (ICPEA)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICPEA53519.2022.9744672","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Mitigation of Voltage Level and Real Power Loss in Transmission System via Optimal UPFC Placement
In a large scale power network, maintaining the magnitude of bus voltages within nominal operating level at all buses is a vital requirement. With such condition, the system will have an optimal transmission line performance with minimum power losses and no overloading issue. To achieve this, the power flow along transmission line ought to be properly controlled using special devices like the Unified Power Flow Controller (UPFC) - a multipurpose device which can control power flow by modifying the voltage magnitude, phase angle and impedance of transmission lines. Hence, this paper proposes a technique for mitigating voltage level and real power losses in transmission system using optimal placement of UPFC and Evolutionary Programming (EP). The implementation of the proposed technique involved IEEE 14-bus reliability test system. Experiment and analysis has justified the capability of EP-based UPFC placement for voltage stability improvement and power loss minimization as well.