架空输电线路屏蔽失效导致220kv变电站雷电过电压

Margreta P. Vasileva, Danail Stanchev
{"title":"架空输电线路屏蔽失效导致220kv变电站雷电过电压","authors":"Margreta P. Vasileva, Danail Stanchev","doi":"10.1109/BULEF.2018.8646957","DOIUrl":null,"url":null,"abstract":"Lightning strokes on overhead transmission lines cause overvoltage surges, which propagate along the power line in the form of traveling waves. These overvoltages endangered the reliability of overhead transmission line and substation equipment. Lightning overvoltages are one of the most important factors in designing of substation and overhead lines insulation. This paper presents various lightning overvoltages in real electrical substation 220 kV due to shielding failure of overhead transmission line based on model study with ATP-EMTP software.","PeriodicalId":416020,"journal":{"name":"2018 10th Electrical Engineering Faculty Conference (BulEF)","volume":"24 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2018-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"7","resultStr":"{\"title\":\"Lightning overvoltages in electrical substation 220 kv due to shielding failure of overhead transmission line\",\"authors\":\"Margreta P. Vasileva, Danail Stanchev\",\"doi\":\"10.1109/BULEF.2018.8646957\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Lightning strokes on overhead transmission lines cause overvoltage surges, which propagate along the power line in the form of traveling waves. These overvoltages endangered the reliability of overhead transmission line and substation equipment. Lightning overvoltages are one of the most important factors in designing of substation and overhead lines insulation. This paper presents various lightning overvoltages in real electrical substation 220 kV due to shielding failure of overhead transmission line based on model study with ATP-EMTP software.\",\"PeriodicalId\":416020,\"journal\":{\"name\":\"2018 10th Electrical Engineering Faculty Conference (BulEF)\",\"volume\":\"24 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2018-09-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"7\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2018 10th Electrical Engineering Faculty Conference (BulEF)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/BULEF.2018.8646957\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2018 10th Electrical Engineering Faculty Conference (BulEF)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/BULEF.2018.8646957","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 7

摘要

架空输电线路上的雷击引起过电压浪涌,过电压浪涌以行波的形式沿电力线传播。这些过电压危及架空输电线路和变电站设备的可靠性。雷电过电压是变电站和架空线路绝缘设计的重要因素之一。本文利用ATP-EMTP软件对实际变电站220kv因架空输电线路屏蔽失效而产生的各种雷电过电压进行了模型研究。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Lightning overvoltages in electrical substation 220 kv due to shielding failure of overhead transmission line
Lightning strokes on overhead transmission lines cause overvoltage surges, which propagate along the power line in the form of traveling waves. These overvoltages endangered the reliability of overhead transmission line and substation equipment. Lightning overvoltages are one of the most important factors in designing of substation and overhead lines insulation. This paper presents various lightning overvoltages in real electrical substation 220 kV due to shielding failure of overhead transmission line based on model study with ATP-EMTP software.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Short-term power output forecasting of the photovoltaics in Bulgaria Coordination of the relay protection settings against phase to phase faults in electric power lines 20 kV A possibility for improving voltage quality intended for sensitive consumers Simulation of probabilistic models Investigation of the Relay Protection Operation and the Electrical Safety at the Presence of Predominant Cable Part in Medium Voltage Power Lines
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1