风力发电系统中双馈感应发电机的电网同步

S. Demirbas, S. Bayhan
{"title":"风力发电系统中双馈感应发电机的电网同步","authors":"S. Demirbas, S. Bayhan","doi":"10.1109/POWERENG.2011.6036502","DOIUrl":null,"url":null,"abstract":"This paper presents a synchronization algorithm for grid connection of a doubly fed induction generator (DFIG) in wind generation system. The vector control scheme is used for the variable speed DFIG operation and to compensate phase difference between grid and DFIG stator voltages a PLL algorithm is used. After the synchronization, the generator is connected to the grid. A laboratory test bench has been set up in order to verify developed algorithm. The experimental set consists of a DFIG, variable speed induction machine and a back-to-back converter. The control algorithms run on eZdsp F2812 target equipped with a TI TMS320F2812 DSP. The experimental result shows that soft and fast synchronization is achieved at the minimum rotating speed.","PeriodicalId":166144,"journal":{"name":"2011 International Conference on Power Engineering, Energy and Electrical Drives","volume":"5 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2011-05-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"18","resultStr":"{\"title\":\"Grid synchronization of doubly fed induction generator in wind power systems\",\"authors\":\"S. Demirbas, S. Bayhan\",\"doi\":\"10.1109/POWERENG.2011.6036502\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper presents a synchronization algorithm for grid connection of a doubly fed induction generator (DFIG) in wind generation system. The vector control scheme is used for the variable speed DFIG operation and to compensate phase difference between grid and DFIG stator voltages a PLL algorithm is used. After the synchronization, the generator is connected to the grid. A laboratory test bench has been set up in order to verify developed algorithm. The experimental set consists of a DFIG, variable speed induction machine and a back-to-back converter. The control algorithms run on eZdsp F2812 target equipped with a TI TMS320F2812 DSP. The experimental result shows that soft and fast synchronization is achieved at the minimum rotating speed.\",\"PeriodicalId\":166144,\"journal\":{\"name\":\"2011 International Conference on Power Engineering, Energy and Electrical Drives\",\"volume\":\"5 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2011-05-11\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"18\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2011 International Conference on Power Engineering, Energy and Electrical Drives\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/POWERENG.2011.6036502\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2011 International Conference on Power Engineering, Energy and Electrical Drives","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/POWERENG.2011.6036502","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 18

摘要

提出了风力发电系统中双馈感应发电机并网的同步算法。采用矢量控制方案实现DFIG的变速运行,并采用锁相环算法补偿电网与DFIG定子电压之间的相位差。同步完成后,发电机并网。为了验证所开发的算法,建立了实验室试验台。实验装置由DFIG、变速感应电机和背靠背变换器组成。控制算法运行在装有TI TMS320F2812 DSP的eZdsp F2812靶上。实验结果表明,在最小转速下实现了软同步和快速同步。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Grid synchronization of doubly fed induction generator in wind power systems
This paper presents a synchronization algorithm for grid connection of a doubly fed induction generator (DFIG) in wind generation system. The vector control scheme is used for the variable speed DFIG operation and to compensate phase difference between grid and DFIG stator voltages a PLL algorithm is used. After the synchronization, the generator is connected to the grid. A laboratory test bench has been set up in order to verify developed algorithm. The experimental set consists of a DFIG, variable speed induction machine and a back-to-back converter. The control algorithms run on eZdsp F2812 target equipped with a TI TMS320F2812 DSP. The experimental result shows that soft and fast synchronization is achieved at the minimum rotating speed.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Low cost DC lines PLC based photovoltaic plants parameters smart monitoring communications and control module Smart meters for distributed filtering of high harmonics in Smart Grid FPGA controller for power converters with integrated oscilloscope and graphical user interface On the square arc voltage waveform model in magnetic discharge lamp studies Interplay of Smart Grids and Intelligent Systems and Control
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1