选择性谐波补偿有源电力滤波器的新型源电流检测控制

Qian Fang, Xueqin Wu, Jinjun Liu
{"title":"选择性谐波补偿有源电力滤波器的新型源电流检测控制","authors":"Qian Fang, Xueqin Wu, Jinjun Liu","doi":"10.1109/IPEMC.2009.5157801","DOIUrl":null,"url":null,"abstract":"In industrial application, the parallel active power filter (PAPF) is used most widely to eliminate the current distortion. It can be classified into two types according different current detection method. One is the load current detection type, and the other is the source current detection type. Load current detection method is an open-loop system, so both time delay and parameter deviation of the PAPF (especially in harmonic detector of PAPF) can cause incorrect compensation and unwanted remaining harmonics in the source current. Source current detection is a closed-loop system, while in traditional source current detection control method, system stability and performance of harmonic elimination is incompatible. In this paper a novel source current detection control of PAPF with selective harmonic compensation is proposed. Implementation of the proposed method in either synchronous or stationary frame is given in this paper. This method can ensure both the excellent performance of PAPF and the system stability. Moreover, this control method is insensitive to time delay and parameter deviation of the PAPF. Finally, simulation and experiment results are presented to demonstrate the conclusions.","PeriodicalId":375971,"journal":{"name":"2009 IEEE 6th International Power Electronics and Motion Control Conference","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2009-05-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":"{\"title\":\"Novel source current detection control of active power filter with selective harmonic compensation\",\"authors\":\"Qian Fang, Xueqin Wu, Jinjun Liu\",\"doi\":\"10.1109/IPEMC.2009.5157801\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"In industrial application, the parallel active power filter (PAPF) is used most widely to eliminate the current distortion. It can be classified into two types according different current detection method. One is the load current detection type, and the other is the source current detection type. Load current detection method is an open-loop system, so both time delay and parameter deviation of the PAPF (especially in harmonic detector of PAPF) can cause incorrect compensation and unwanted remaining harmonics in the source current. Source current detection is a closed-loop system, while in traditional source current detection control method, system stability and performance of harmonic elimination is incompatible. In this paper a novel source current detection control of PAPF with selective harmonic compensation is proposed. Implementation of the proposed method in either synchronous or stationary frame is given in this paper. This method can ensure both the excellent performance of PAPF and the system stability. Moreover, this control method is insensitive to time delay and parameter deviation of the PAPF. Finally, simulation and experiment results are presented to demonstrate the conclusions.\",\"PeriodicalId\":375971,\"journal\":{\"name\":\"2009 IEEE 6th International Power Electronics and Motion Control Conference\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2009-05-17\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2009 IEEE 6th International Power Electronics and Motion Control Conference\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/IPEMC.2009.5157801\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2009 IEEE 6th International Power Electronics and Motion Control Conference","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/IPEMC.2009.5157801","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

摘要

在工业应用中,为了消除电流畸变,并联有源电力滤波器(PAPF)的应用最为广泛。根据电流检测方法的不同,可分为两种类型。一种是负载电流检测型,另一种是源电流检测型。负载电流检测方法是一个开环系统,因此PAPF(特别是PAPF的谐波检测器)的时间延迟和参数偏差都可能导致不正确的补偿和源电流中多余的剩余谐波。源电流检测是一个闭环系统,而在传统的源电流检测控制方法中,系统的稳定性与谐波消除性能是不相容的。本文提出了一种具有选择性谐波补偿的PAPF源电流检测控制方法。本文给出了该方法在同步或静止框架下的实现。该方法既保证了PAPF的优良性能,又保证了系统的稳定性。此外,该控制方法对PAPF的时滞和参数偏差不敏感。最后,通过仿真和实验验证了本文的结论。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Novel source current detection control of active power filter with selective harmonic compensation
In industrial application, the parallel active power filter (PAPF) is used most widely to eliminate the current distortion. It can be classified into two types according different current detection method. One is the load current detection type, and the other is the source current detection type. Load current detection method is an open-loop system, so both time delay and parameter deviation of the PAPF (especially in harmonic detector of PAPF) can cause incorrect compensation and unwanted remaining harmonics in the source current. Source current detection is a closed-loop system, while in traditional source current detection control method, system stability and performance of harmonic elimination is incompatible. In this paper a novel source current detection control of PAPF with selective harmonic compensation is proposed. Implementation of the proposed method in either synchronous or stationary frame is given in this paper. This method can ensure both the excellent performance of PAPF and the system stability. Moreover, this control method is insensitive to time delay and parameter deviation of the PAPF. Finally, simulation and experiment results are presented to demonstrate the conclusions.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Study and implementation of a single-stage three-phase AC-DC converter A resonant gate-drive circuit capable of high-frequency and high-efficiency operation Study of multi-level rectifier in high power system based on a novel virtual flux observer Power control strategy of electronic ballast for Metal Halide Lamps Design of a digital control IC of a current source based on a three-phase controlled rectifier
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1