Wei Huang, Lifei Zhang, Xiaogang Wu, Chengxiang Li, Jie Zhang, Chen-Han Wu, Run Huang, Mingkang Wu
{"title":"DXB直流工程中直流限频控制的研究与工程应用","authors":"Wei Huang, Lifei Zhang, Xiaogang Wu, Chengxiang Li, Jie Zhang, Chen-Han Wu, Run Huang, Mingkang Wu","doi":"10.1109/CIEEC50170.2021.9510198","DOIUrl":null,"url":null,"abstract":"The frequency limit controller, or FLC, is an important measure for grid frequency stability control, and has been widely used in DC projects. DXB UHVDC project is faced with the problems of increasing frequency instability of the Yunnan power grid, as it runs asynchronously from the main grid, and the shortage of the opening unit in the initial stage of production. The configuration of FLC is very important. It analyzes two kinds of FLC control logic used in current DC project of China Southern Power Grid and compares the results of two kinds of control logic response through simulation test. The FLC configuration and parameter selection of DXB UHVDC are explained, and the response characteristics of FLC under the typical fault under the isolated islanding system are verified through simulation. And verify its function in DXB R TDS simulation platform as well as field test.","PeriodicalId":110429,"journal":{"name":"2021 IEEE 4th International Electrical and Energy Conference (CIEEC)","volume":"15 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2021-05-28","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Research and Engineering Application of DC Frequency Limit Control in DXB DC Project\",\"authors\":\"Wei Huang, Lifei Zhang, Xiaogang Wu, Chengxiang Li, Jie Zhang, Chen-Han Wu, Run Huang, Mingkang Wu\",\"doi\":\"10.1109/CIEEC50170.2021.9510198\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The frequency limit controller, or FLC, is an important measure for grid frequency stability control, and has been widely used in DC projects. DXB UHVDC project is faced with the problems of increasing frequency instability of the Yunnan power grid, as it runs asynchronously from the main grid, and the shortage of the opening unit in the initial stage of production. The configuration of FLC is very important. It analyzes two kinds of FLC control logic used in current DC project of China Southern Power Grid and compares the results of two kinds of control logic response through simulation test. The FLC configuration and parameter selection of DXB UHVDC are explained, and the response characteristics of FLC under the typical fault under the isolated islanding system are verified through simulation. And verify its function in DXB R TDS simulation platform as well as field test.\",\"PeriodicalId\":110429,\"journal\":{\"name\":\"2021 IEEE 4th International Electrical and Energy Conference (CIEEC)\",\"volume\":\"15 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2021-05-28\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2021 IEEE 4th International Electrical and Energy Conference (CIEEC)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/CIEEC50170.2021.9510198\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2021 IEEE 4th International Electrical and Energy Conference (CIEEC)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/CIEEC50170.2021.9510198","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Research and Engineering Application of DC Frequency Limit Control in DXB DC Project
The frequency limit controller, or FLC, is an important measure for grid frequency stability control, and has been widely used in DC projects. DXB UHVDC project is faced with the problems of increasing frequency instability of the Yunnan power grid, as it runs asynchronously from the main grid, and the shortage of the opening unit in the initial stage of production. The configuration of FLC is very important. It analyzes two kinds of FLC control logic used in current DC project of China Southern Power Grid and compares the results of two kinds of control logic response through simulation test. The FLC configuration and parameter selection of DXB UHVDC are explained, and the response characteristics of FLC under the typical fault under the isolated islanding system are verified through simulation. And verify its function in DXB R TDS simulation platform as well as field test.