{"title":"应用实验程序在功能环境下对晶体振荡器进行了表征","authors":"G. Robichon, A. Debaisieux, J. Aubry","doi":"10.1109/FREQ.1989.68873","DOIUrl":null,"url":null,"abstract":"The methods used by CEPE in following areas are presented: g sensibility dynamic test (spectrum analysis of phase fluctuation under known random vibrations); acoustic sensitivity (spectrum analysis of phase fluctuation under known acoustic excitation); power supply sensitivity (spectrum analysis of phase fluctuation with ripple on power supply); barometric (pressure) sensitivity; and magnetic field sensitivity. Description of test equipments and procedures of these various measurements are given. Typical results (including reproducibility) are presented.<<ETX>>","PeriodicalId":294361,"journal":{"name":"Proceedings of the 43rd Annual Symposium on Frequency Control","volume":"23 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1989-05-31","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":"{\"title\":\"Experimental procedure applied to characterize crystal oscillator under functional environment\",\"authors\":\"G. Robichon, A. Debaisieux, J. Aubry\",\"doi\":\"10.1109/FREQ.1989.68873\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The methods used by CEPE in following areas are presented: g sensibility dynamic test (spectrum analysis of phase fluctuation under known random vibrations); acoustic sensitivity (spectrum analysis of phase fluctuation under known acoustic excitation); power supply sensitivity (spectrum analysis of phase fluctuation with ripple on power supply); barometric (pressure) sensitivity; and magnetic field sensitivity. Description of test equipments and procedures of these various measurements are given. Typical results (including reproducibility) are presented.<<ETX>>\",\"PeriodicalId\":294361,\"journal\":{\"name\":\"Proceedings of the 43rd Annual Symposium on Frequency Control\",\"volume\":\"23 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1989-05-31\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"3\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Proceedings of the 43rd Annual Symposium on Frequency Control\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/FREQ.1989.68873\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings of the 43rd Annual Symposium on Frequency Control","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/FREQ.1989.68873","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Experimental procedure applied to characterize crystal oscillator under functional environment
The methods used by CEPE in following areas are presented: g sensibility dynamic test (spectrum analysis of phase fluctuation under known random vibrations); acoustic sensitivity (spectrum analysis of phase fluctuation under known acoustic excitation); power supply sensitivity (spectrum analysis of phase fluctuation with ripple on power supply); barometric (pressure) sensitivity; and magnetic field sensitivity. Description of test equipments and procedures of these various measurements are given. Typical results (including reproducibility) are presented.<>