大电网参数补偿装置最优值确定方法

M. Bělík, V. Kuchanskyy, Lykhovyd Yuri, O. Rubanenko
{"title":"大电网参数补偿装置最优值确定方法","authors":"M. Bělík, V. Kuchanskyy, Lykhovyd Yuri, O. Rubanenko","doi":"10.1109/ESS57819.2022.9969291","DOIUrl":null,"url":null,"abstract":"The given method of optimizing the modes of main electric networks allows obtaining a universal approach for solving such tasks as minimizing the total losses of active power and compensating excess flows of reactive power. The methodology for selecting the parameters of compensating devices of controlled ultra-high voltage power transmissions with intermediate systems to ensure the balance of reactive power has been substantiated. An analytical solution to the problem of selecting the parameters of the compensating ultra-high voltage power transmission line with one intermediate system was obtained. An approach to solving the problem of optimization of the main electrical network is presented, taking into account the provision of reactive power balance. The objective function and its optimization criteria are described. The method of optimizing the mode of the electrical network according to voltage and reactive power was developed with an assessment of the effectiveness of the use of controlled compensating compensation devices, and the possibility of applying this approach was revealed. Recommendations are given on the use of reactive power compensators to improve the reliability and quality of power supply. The technique has been developed for evaluating the efficiency of controlled nodes based on optimizing the mode of electrical networks containing such nodes. In the work, two problems are solved when choosing installation sites and values of parameters of compensating devices: balancing reactive power and optimizing the operating modes of the main electrical network according to the criterion of minimum active power losses. The most efficient hardware based on static devices of the FACTS technological platform is proposed.","PeriodicalId":432063,"journal":{"name":"2022 IEEE 8th International Conference on Energy Smart Systems (ESS)","volume":"72 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2022-10-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Optimal Value Determining Method of Parameters Compensating Devices of Bulk Electric Networks\",\"authors\":\"M. Bělík, V. Kuchanskyy, Lykhovyd Yuri, O. Rubanenko\",\"doi\":\"10.1109/ESS57819.2022.9969291\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The given method of optimizing the modes of main electric networks allows obtaining a universal approach for solving such tasks as minimizing the total losses of active power and compensating excess flows of reactive power. The methodology for selecting the parameters of compensating devices of controlled ultra-high voltage power transmissions with intermediate systems to ensure the balance of reactive power has been substantiated. An analytical solution to the problem of selecting the parameters of the compensating ultra-high voltage power transmission line with one intermediate system was obtained. An approach to solving the problem of optimization of the main electrical network is presented, taking into account the provision of reactive power balance. The objective function and its optimization criteria are described. The method of optimizing the mode of the electrical network according to voltage and reactive power was developed with an assessment of the effectiveness of the use of controlled compensating compensation devices, and the possibility of applying this approach was revealed. Recommendations are given on the use of reactive power compensators to improve the reliability and quality of power supply. The technique has been developed for evaluating the efficiency of controlled nodes based on optimizing the mode of electrical networks containing such nodes. In the work, two problems are solved when choosing installation sites and values of parameters of compensating devices: balancing reactive power and optimizing the operating modes of the main electrical network according to the criterion of minimum active power losses. The most efficient hardware based on static devices of the FACTS technological platform is proposed.\",\"PeriodicalId\":432063,\"journal\":{\"name\":\"2022 IEEE 8th International Conference on Energy Smart Systems (ESS)\",\"volume\":\"72 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2022-10-12\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2022 IEEE 8th International Conference on Energy Smart Systems (ESS)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ESS57819.2022.9969291\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2022 IEEE 8th International Conference on Energy Smart Systems (ESS)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ESS57819.2022.9969291","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

所给出的优化主电网模式的方法,为解决使有功总损耗最小和补偿多余无功流等问题提供了一种通用的方法。给出了控制超高压中间输电系统补偿装置参数的选择方法,以保证无功平衡。给出了单中间系统补偿特高压输电线路参数选择问题的解析解。提出了一种考虑无功平衡提供的主电网优化问题的解决方法。描述了目标函数及其优化准则。提出了根据电压和无功功率优化电网模式的方法,并对控制补偿装置的使用效果进行了评估,揭示了该方法应用的可能性。对无功补偿器的使用提出了建议,以提高供电的可靠性和质量。该技术是基于优化包含控制节点的电网模式来评估控制节点的效率。在工作中,解决了补偿装置安装地点和参数取值选择的两个问题:根据有功损耗最小准则平衡无功功率和优化主电网运行方式。提出了基于静态设备的FACTS技术平台的最高效硬件。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Optimal Value Determining Method of Parameters Compensating Devices of Bulk Electric Networks
The given method of optimizing the modes of main electric networks allows obtaining a universal approach for solving such tasks as minimizing the total losses of active power and compensating excess flows of reactive power. The methodology for selecting the parameters of compensating devices of controlled ultra-high voltage power transmissions with intermediate systems to ensure the balance of reactive power has been substantiated. An analytical solution to the problem of selecting the parameters of the compensating ultra-high voltage power transmission line with one intermediate system was obtained. An approach to solving the problem of optimization of the main electrical network is presented, taking into account the provision of reactive power balance. The objective function and its optimization criteria are described. The method of optimizing the mode of the electrical network according to voltage and reactive power was developed with an assessment of the effectiveness of the use of controlled compensating compensation devices, and the possibility of applying this approach was revealed. Recommendations are given on the use of reactive power compensators to improve the reliability and quality of power supply. The technique has been developed for evaluating the efficiency of controlled nodes based on optimizing the mode of electrical networks containing such nodes. In the work, two problems are solved when choosing installation sites and values of parameters of compensating devices: balancing reactive power and optimizing the operating modes of the main electrical network according to the criterion of minimum active power losses. The most efficient hardware based on static devices of the FACTS technological platform is proposed.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Monitoring of loss power components in three-phase low-voltage power supply systems A Fault Tolerant Multilevel Converter Topology for an 8/6 SRM Drive Based on a Cross-Switched Configuration Adjustment of Two Circuits System of Active Shielding of the Magnetic Field Generated by Overhead Power Lines Analysis of the Probable Decrease of Load Shedding Reserve in Power System of Ukraine at Installed Capacity of Renewable Energy Sources Possibilities of Electricity Generation Using Small Wind Generators in Eastern Ukraine
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1