{"title":"减轻电压下降和膨胀对IV型风力发电机系统的影响","authors":"T. Das, Jingxin Zhang","doi":"10.1109/AUPEC.2017.8282438","DOIUrl":null,"url":null,"abstract":"This paper proposes a unique coordinated ride-through capability enhancement scheme for Type IV wind generators to counter the impact of symmetrical and asymmetrical voltage swells. A novel protection hardware configuration is utilized to restrict the dc-link overvoltage and undervoltage in the event of voltage swells at the Point of Common Coupling (PCC), which would otherwise damage the converter. Moreover, a reactive power flow management algorithm is implemented to support the grid voltage during the transient event. A supervisory controller is used to control the insertion of the protection hardware and also to regulate the reactive power flow between the generator and grid. It is observed that there is substantial improvement in ride-through performance. A 10-MW Wound Rotor Synchrnous Generator (WRSG) wind farm in MATLAB/Simscape Power Systems is utilized to validate the effectiveness of the scheme. The 10 MW wind farm consists of 5 × 2-MW wind generators.","PeriodicalId":155608,"journal":{"name":"2017 Australasian Universities Power Engineering Conference (AUPEC)","volume":"83 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2017-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"4","resultStr":"{\"title\":\"Mitigating the impact of voltage sags and swells on type IV wind generator systems\",\"authors\":\"T. Das, Jingxin Zhang\",\"doi\":\"10.1109/AUPEC.2017.8282438\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper proposes a unique coordinated ride-through capability enhancement scheme for Type IV wind generators to counter the impact of symmetrical and asymmetrical voltage swells. A novel protection hardware configuration is utilized to restrict the dc-link overvoltage and undervoltage in the event of voltage swells at the Point of Common Coupling (PCC), which would otherwise damage the converter. Moreover, a reactive power flow management algorithm is implemented to support the grid voltage during the transient event. A supervisory controller is used to control the insertion of the protection hardware and also to regulate the reactive power flow between the generator and grid. It is observed that there is substantial improvement in ride-through performance. A 10-MW Wound Rotor Synchrnous Generator (WRSG) wind farm in MATLAB/Simscape Power Systems is utilized to validate the effectiveness of the scheme. The 10 MW wind farm consists of 5 × 2-MW wind generators.\",\"PeriodicalId\":155608,\"journal\":{\"name\":\"2017 Australasian Universities Power Engineering Conference (AUPEC)\",\"volume\":\"83 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2017-11-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"4\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2017 Australasian Universities Power Engineering Conference (AUPEC)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/AUPEC.2017.8282438\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2017 Australasian Universities Power Engineering Conference (AUPEC)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/AUPEC.2017.8282438","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 4
摘要
本文提出了一种独特的四型风力发电机协调穿越能力增强方案,以应对对称和不对称电压波动的影响。采用一种新颖的保护硬件配置,在共耦合点(PCC)电压膨胀时限制直流链路过压和欠压,否则会损坏变换器。此外,还实现了一种无功潮流管理算法,以支持暂态事件期间的电网电压。监控控制器用于控制保护硬件的插入,并调节发电机和电网之间的无功功率流。可以观察到,穿越性能有实质性的改善。利用MATLAB/Simscape Power Systems中的10 mw绕线转子同步发电机(WRSG)风电场验证了该方案的有效性。10兆瓦的风电场由5 × 2兆瓦的风力发电机组成。
Mitigating the impact of voltage sags and swells on type IV wind generator systems
This paper proposes a unique coordinated ride-through capability enhancement scheme for Type IV wind generators to counter the impact of symmetrical and asymmetrical voltage swells. A novel protection hardware configuration is utilized to restrict the dc-link overvoltage and undervoltage in the event of voltage swells at the Point of Common Coupling (PCC), which would otherwise damage the converter. Moreover, a reactive power flow management algorithm is implemented to support the grid voltage during the transient event. A supervisory controller is used to control the insertion of the protection hardware and also to regulate the reactive power flow between the generator and grid. It is observed that there is substantial improvement in ride-through performance. A 10-MW Wound Rotor Synchrnous Generator (WRSG) wind farm in MATLAB/Simscape Power Systems is utilized to validate the effectiveness of the scheme. The 10 MW wind farm consists of 5 × 2-MW wind generators.