{"title":"IMRT的验证、分析和性能评估:通过移动MLC角度和幻影位置来模拟剂量传递","authors":"A. Zhdanov, V. I. Borisov, L. Dorosinsky","doi":"10.1109/ICISCT47635.2019.9012047","DOIUrl":null,"url":null,"abstract":"In modern radiology treatment workflow, verification is a critical process for determining the validity of specific treatment planning. In this article, we verified a treatment plan by modeling of dose delivery by shifting MLC angel and phantom position. The study result shows that any error during the verification process such as an error in the MLC angle or the phantom positioning may lead to different passing rate and refuse a plan, which it is correct originally.","PeriodicalId":170576,"journal":{"name":"2019 International Conference on Information Science and Communications Technologies (ICISCT)","volume":"41 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2019-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"IMRT Verification, Analysis and Performance Evaluations: Modeling of Dose Delivery by Shifting MLC Angel and Phantom Position\",\"authors\":\"A. Zhdanov, V. I. Borisov, L. Dorosinsky\",\"doi\":\"10.1109/ICISCT47635.2019.9012047\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"In modern radiology treatment workflow, verification is a critical process for determining the validity of specific treatment planning. In this article, we verified a treatment plan by modeling of dose delivery by shifting MLC angel and phantom position. The study result shows that any error during the verification process such as an error in the MLC angle or the phantom positioning may lead to different passing rate and refuse a plan, which it is correct originally.\",\"PeriodicalId\":170576,\"journal\":{\"name\":\"2019 International Conference on Information Science and Communications Technologies (ICISCT)\",\"volume\":\"41 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2019-11-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2019 International Conference on Information Science and Communications Technologies (ICISCT)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICISCT47635.2019.9012047\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2019 International Conference on Information Science and Communications Technologies (ICISCT)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICISCT47635.2019.9012047","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
IMRT Verification, Analysis and Performance Evaluations: Modeling of Dose Delivery by Shifting MLC Angel and Phantom Position
In modern radiology treatment workflow, verification is a critical process for determining the validity of specific treatment planning. In this article, we verified a treatment plan by modeling of dose delivery by shifting MLC angel and phantom position. The study result shows that any error during the verification process such as an error in the MLC angle or the phantom positioning may lead to different passing rate and refuse a plan, which it is correct originally.