不平衡负载三相四线并联有源电力滤波器的TS型模糊控制器

Harsha Vanjani, U. K. Choudhury, Meha Sharma, Bhavesh J. Vanjani
{"title":"不平衡负载三相四线并联有源电力滤波器的TS型模糊控制器","authors":"Harsha Vanjani, U. K. Choudhury, Meha Sharma, Bhavesh J. Vanjani","doi":"10.1109/POWERI.2016.8077227","DOIUrl":null,"url":null,"abstract":"Usage of Active power filters is increased in this moderen era as they are capable to reduce harmonics effectively. Shunt Active Filters are proven to diminish harmonics compared to all other devices. Many control strategies has been developed till date to control Shunt Active Power filter. In soft computing techniques generally fuzzy logic has been used with mamdani type of fuzzy logic controller. This paper presents comparison of mamdani and TS type fuzzy logic controller to control the three-phase shunt active power filter. Fuzzy logic method is used to tune PID controller to autotune controller. Instantaneous Reactive Power theory is implemented to generate reference currents. Simulation is done in MATLAB to verify the results.","PeriodicalId":332286,"journal":{"name":"2016 IEEE 7th Power India International Conference (PIICON)","volume":"1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2016-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"7","resultStr":"{\"title\":\"Takagi-sugeno (TS)-type fuzzy logic controller for three-phase four-wire shunt active power filter for unbalanced load\",\"authors\":\"Harsha Vanjani, U. K. Choudhury, Meha Sharma, Bhavesh J. Vanjani\",\"doi\":\"10.1109/POWERI.2016.8077227\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Usage of Active power filters is increased in this moderen era as they are capable to reduce harmonics effectively. Shunt Active Filters are proven to diminish harmonics compared to all other devices. Many control strategies has been developed till date to control Shunt Active Power filter. In soft computing techniques generally fuzzy logic has been used with mamdani type of fuzzy logic controller. This paper presents comparison of mamdani and TS type fuzzy logic controller to control the three-phase shunt active power filter. Fuzzy logic method is used to tune PID controller to autotune controller. Instantaneous Reactive Power theory is implemented to generate reference currents. Simulation is done in MATLAB to verify the results.\",\"PeriodicalId\":332286,\"journal\":{\"name\":\"2016 IEEE 7th Power India International Conference (PIICON)\",\"volume\":\"1 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2016-11-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"7\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2016 IEEE 7th Power India International Conference (PIICON)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/POWERI.2016.8077227\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2016 IEEE 7th Power India International Conference (PIICON)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/POWERI.2016.8077227","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 7

摘要

有源电力滤波器的使用在这个现代时代有所增加,因为它们能够有效地减少谐波。与所有其他设备相比,并联有源滤波器已被证明可以减少谐波。目前已经开发了许多控制策略来控制并联有源电力滤波器。在软计算技术中,模糊逻辑通常与mamdani型模糊逻辑控制器一起使用。本文比较了mamdani和TS型模糊控制器对三相并联有源电力滤波器的控制效果。采用模糊逻辑方法对PID控制器进行自整定。采用瞬时无功原理产生参考电流。在MATLAB中进行了仿真验证。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Takagi-sugeno (TS)-type fuzzy logic controller for three-phase four-wire shunt active power filter for unbalanced load
Usage of Active power filters is increased in this moderen era as they are capable to reduce harmonics effectively. Shunt Active Filters are proven to diminish harmonics compared to all other devices. Many control strategies has been developed till date to control Shunt Active Power filter. In soft computing techniques generally fuzzy logic has been used with mamdani type of fuzzy logic controller. This paper presents comparison of mamdani and TS type fuzzy logic controller to control the three-phase shunt active power filter. Fuzzy logic method is used to tune PID controller to autotune controller. Instantaneous Reactive Power theory is implemented to generate reference currents. Simulation is done in MATLAB to verify the results.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Detection of power quality disturbances in the utility grid with solar energy using S-transform Full bridge level doubling network assisted multilevel DC link inverter Distribution system expansion planning incorporating distributed generation A solar PV system controlled by least sum of exponentials algorithm Photo-voltaic system for refrigeration plants in isolated areas
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1