L. Anishchenko, S. Ivashov, I. Catapano, L. Crocco, G. Gennarelli, F. Soldovieri
{"title":"用于生命体征表征的雷达:两种不同频段系统的比较","authors":"L. Anishchenko, S. Ivashov, I. Catapano, L. Crocco, G. Gennarelli, F. Soldovieri","doi":"10.1109/IWAGPR.2013.6601536","DOIUrl":null,"url":null,"abstract":"This paper deals with the exploitation of two bio-radar systems (4 GHz and 14 GHZ frequency) developed at Remote Sensing Laboratory of the Bauman Moscow State Technical University for vital signs characterization (breathing and heartbeat). In particular, an experiment has been performed with the two radar systems, in order to appraise the different performance, in terms of detection and accuracy, with respect to vital signs estimation. For this experiment, the data have been processed by means of a recently developed approach that allows us to perform the parameter estimation (and therefore the overall monitoring process) in an automatic way.","PeriodicalId":257117,"journal":{"name":"2013 7th International Workshop on Advanced Ground Penetrating Radar","volume":"1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2013-07-02","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"4","resultStr":"{\"title\":\"Radar for vital signs characterization: A comparison between two different frequency band systems\",\"authors\":\"L. Anishchenko, S. Ivashov, I. Catapano, L. Crocco, G. Gennarelli, F. Soldovieri\",\"doi\":\"10.1109/IWAGPR.2013.6601536\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper deals with the exploitation of two bio-radar systems (4 GHz and 14 GHZ frequency) developed at Remote Sensing Laboratory of the Bauman Moscow State Technical University for vital signs characterization (breathing and heartbeat). In particular, an experiment has been performed with the two radar systems, in order to appraise the different performance, in terms of detection and accuracy, with respect to vital signs estimation. For this experiment, the data have been processed by means of a recently developed approach that allows us to perform the parameter estimation (and therefore the overall monitoring process) in an automatic way.\",\"PeriodicalId\":257117,\"journal\":{\"name\":\"2013 7th International Workshop on Advanced Ground Penetrating Radar\",\"volume\":\"1 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2013-07-02\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"4\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2013 7th International Workshop on Advanced Ground Penetrating Radar\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/IWAGPR.2013.6601536\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2013 7th International Workshop on Advanced Ground Penetrating Radar","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/IWAGPR.2013.6601536","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 4

摘要

本文讨论了莫斯科鲍曼国立技术大学遥感实验室开发的两种生物雷达系统(4 GHz和14 GHz频率)用于生命体征表征(呼吸和心跳)的开发。特别地,对这两种雷达系统进行了实验,以评估在检测和精度方面的不同性能,以及在生命体征估计方面的不同性能。对于这个实验,数据已经通过一种最近开发的方法进行了处理,该方法允许我们以自动的方式执行参数估计(因此整个监测过程)。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Radar for vital signs characterization: A comparison between two different frequency band systems
This paper deals with the exploitation of two bio-radar systems (4 GHz and 14 GHZ frequency) developed at Remote Sensing Laboratory of the Bauman Moscow State Technical University for vital signs characterization (breathing and heartbeat). In particular, an experiment has been performed with the two radar systems, in order to appraise the different performance, in terms of detection and accuracy, with respect to vital signs estimation. For this experiment, the data have been processed by means of a recently developed approach that allows us to perform the parameter estimation (and therefore the overall monitoring process) in an automatic way.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
An evaluation of the early-time GPR amplitude technique for electrical conductivity monitoring Non destructive assessment of Hot Mix Asphalt compaction with a step frequency radar: Case study Towards physically-based filtering of the soil surface, antenna and coupling effects from near-field GPR data for improved subsurface imaging Time delay and surface roughness estimation by subspace algorithms for pavement survey by radar Applications of a reconfigurable stepped frequency GPR in the chapel of the Holy Spirit, Lecce (Italy)
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1