{"title":"用于机器人活检的二维超声图像的实时针尖定位","authors":"Mert Kaya, Enes Senel, Awais Ahmad, Orcun Orhan, O. Bebek","doi":"10.1109/ICAR.2015.7251432","DOIUrl":null,"url":null,"abstract":"In this paper, real-time needle tip tracking method using 2D ultrasound (US) images for robotic biopsies is presented. In this method, the needle tip is estimated with the Gabor filter based image processing algorithm, and the estimation noise is reduced with the Kalman filter. This paper also presents the needle tip tracking simulation to test accuracy of the Kalman filter under position misalignments and tissue deformations. In order to execute proposed method in real-time, the bin packing method is used and the processing time is reduced by 56%, without a GPU. The proposed method was tested in four different phantoms and water medium. The accuracy of the needle tip estimation was measured with optical tracking system, and root mean square error (RMS) of the tip position is found to be 1.17 mm. The experiments showed that the algorithm could track the needle tip in real-time.","PeriodicalId":432004,"journal":{"name":"2015 International Conference on Advanced Robotics (ICAR)","volume":"28 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2015-07-27","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"22","resultStr":"{\"title\":\"Real-time needle tip localization in 2D ultrasound images for robotic biopsies\",\"authors\":\"Mert Kaya, Enes Senel, Awais Ahmad, Orcun Orhan, O. Bebek\",\"doi\":\"10.1109/ICAR.2015.7251432\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"In this paper, real-time needle tip tracking method using 2D ultrasound (US) images for robotic biopsies is presented. In this method, the needle tip is estimated with the Gabor filter based image processing algorithm, and the estimation noise is reduced with the Kalman filter. This paper also presents the needle tip tracking simulation to test accuracy of the Kalman filter under position misalignments and tissue deformations. In order to execute proposed method in real-time, the bin packing method is used and the processing time is reduced by 56%, without a GPU. The proposed method was tested in four different phantoms and water medium. The accuracy of the needle tip estimation was measured with optical tracking system, and root mean square error (RMS) of the tip position is found to be 1.17 mm. The experiments showed that the algorithm could track the needle tip in real-time.\",\"PeriodicalId\":432004,\"journal\":{\"name\":\"2015 International Conference on Advanced Robotics (ICAR)\",\"volume\":\"28 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2015-07-27\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"22\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2015 International Conference on Advanced Robotics (ICAR)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICAR.2015.7251432\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2015 International Conference on Advanced Robotics (ICAR)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICAR.2015.7251432","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 22

摘要

本文介绍了利用二维超声(US)图像进行机器人活检的实时针尖跟踪方法。该方法采用基于Gabor滤波的图像处理算法对针尖进行估计,并用卡尔曼滤波降低估计噪声。本文还通过针尖跟踪仿真来测试卡尔曼滤波在位置错位和组织变形情况下的精度。为了实时执行所提出的方法,在不使用GPU的情况下,采用bin packing方法,处理时间缩短了56%。该方法在四种不同的幽灵和水介质中进行了测试。利用光学跟踪系统测量了针尖位置的估计精度,得到针尖位置的均方根误差(RMS)为1.17 mm。实验表明,该算法能够实时跟踪针尖。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Real-time needle tip localization in 2D ultrasound images for robotic biopsies
In this paper, real-time needle tip tracking method using 2D ultrasound (US) images for robotic biopsies is presented. In this method, the needle tip is estimated with the Gabor filter based image processing algorithm, and the estimation noise is reduced with the Kalman filter. This paper also presents the needle tip tracking simulation to test accuracy of the Kalman filter under position misalignments and tissue deformations. In order to execute proposed method in real-time, the bin packing method is used and the processing time is reduced by 56%, without a GPU. The proposed method was tested in four different phantoms and water medium. The accuracy of the needle tip estimation was measured with optical tracking system, and root mean square error (RMS) of the tip position is found to be 1.17 mm. The experiments showed that the algorithm could track the needle tip in real-time.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
On the EMG-based torque estimation for humans coupled with a force-controlled elbow exoskeleton The KIT whole-body human motion database Visual matching of stroke order in robotic calligraphy Real-time motion adaptation using relative distance space representation Optimization of the switching surface for the simplest passive dynamic biped
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1