患者特异性放射治疗靶点的设计

M. Heyns, K. Breseman, Christopher L. Lee, B. Bloch, C. Jaffe, H. Xiang
{"title":"患者特异性放射治疗靶点的设计","authors":"M. Heyns, K. Breseman, Christopher L. Lee, B. Bloch, C. Jaffe, H. Xiang","doi":"10.1109/NEBEC.2013.75","DOIUrl":null,"url":null,"abstract":"This paper describes the design of a patient-specific, radiotherapy quality assurance target that can be used to verify a treatment plan by measurement of actual dosage. Staring from a patient's (segmented) MR images, a physical model containing insertable cartridges for holding dosimeters is printed in 3D. Dosimeters can be located at specific locations of interest (e.g., tumor, nerve bundles, urethra). The model (dosimeter insert) can be placed into a pelvis 'shell' and subject to a specified treatment plan. A design for the dosimeter insert can be efficiently fabricated using rapid prototyping techniques.","PeriodicalId":153112,"journal":{"name":"2013 39th Annual Northeast Bioengineering Conference","volume":"42 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2013-04-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":"{\"title\":\"Design of a Patient-Specific Radiotherapy Treatment Target\",\"authors\":\"M. Heyns, K. Breseman, Christopher L. Lee, B. Bloch, C. Jaffe, H. Xiang\",\"doi\":\"10.1109/NEBEC.2013.75\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper describes the design of a patient-specific, radiotherapy quality assurance target that can be used to verify a treatment plan by measurement of actual dosage. Staring from a patient's (segmented) MR images, a physical model containing insertable cartridges for holding dosimeters is printed in 3D. Dosimeters can be located at specific locations of interest (e.g., tumor, nerve bundles, urethra). The model (dosimeter insert) can be placed into a pelvis 'shell' and subject to a specified treatment plan. A design for the dosimeter insert can be efficiently fabricated using rapid prototyping techniques.\",\"PeriodicalId\":153112,\"journal\":{\"name\":\"2013 39th Annual Northeast Bioengineering Conference\",\"volume\":\"42 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2013-04-05\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"3\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2013 39th Annual Northeast Bioengineering Conference\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/NEBEC.2013.75\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2013 39th Annual Northeast Bioengineering Conference","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/NEBEC.2013.75","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 3

摘要

本文描述了一种针对患者的放射治疗质量保证靶标的设计,该靶标可以通过测量实际剂量来验证治疗计划。从病人的(分段的)MR图像中,一个包含可插入的用于容纳剂量计的墨盒的物理模型被3D打印出来。剂量计可放置在感兴趣的特定位置(如肿瘤、神经束、尿道)。该模型(剂量计插入)可以放入骨盆“壳”中,并接受指定的治疗计划。使用快速原型技术可以有效地制作剂量计插入件的设计。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Design of a Patient-Specific Radiotherapy Treatment Target
This paper describes the design of a patient-specific, radiotherapy quality assurance target that can be used to verify a treatment plan by measurement of actual dosage. Staring from a patient's (segmented) MR images, a physical model containing insertable cartridges for holding dosimeters is printed in 3D. Dosimeters can be located at specific locations of interest (e.g., tumor, nerve bundles, urethra). The model (dosimeter insert) can be placed into a pelvis 'shell' and subject to a specified treatment plan. A design for the dosimeter insert can be efficiently fabricated using rapid prototyping techniques.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Comparison between T2 Relaxation Time and Storage Modulus for Agarose Gel The Electroencephalographic Response during a Driving Process: Normal Driving, Turning and Collision Biocompatibility of CaO-Na2O-SiO2/TiO2 Glass Ceramic Scaffolds for Orthopaedic Applications Improvement on Dental Ceramics Using Microwave Sintering Influence of Eccentric Loading and Size of Implant Fixture on the Stress Distribution in the Implant
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1