{"title":"用于骨结构测量的x射线微断层扫描系统","authors":"M. Flynn, D. Reimann, A. Parfitt, D. Fyhrie","doi":"10.1109/NSSMIC.1992.301514","DOIUrl":null,"url":null,"abstract":"A system for very-high-resolution (50 mu m*50 mu m*50 mu m) three-dimensional tomography of small (1 cm*1 cm*1 cm) biological specimen is described. Two-dimensional planar X-ray views of the specimen are acquired by an image intensifier and digital camera system while the specimen is rotated through several hundred positions. The recorded data are processed to obtain spatially accurate estimates of the attenuation line integral and reconstructed using a cone-beam algorithm. Measurements obtained with this system are being used to study the structures found in bone biopsy specimens.<<ETX>>","PeriodicalId":447239,"journal":{"name":"IEEE Conference on Nuclear Science Symposium and Medical Imaging","volume":"316 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1992-10-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"4","resultStr":"{\"title\":\"An X-ray microtomography system for bone structure measurements\",\"authors\":\"M. Flynn, D. Reimann, A. Parfitt, D. Fyhrie\",\"doi\":\"10.1109/NSSMIC.1992.301514\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"A system for very-high-resolution (50 mu m*50 mu m*50 mu m) three-dimensional tomography of small (1 cm*1 cm*1 cm) biological specimen is described. Two-dimensional planar X-ray views of the specimen are acquired by an image intensifier and digital camera system while the specimen is rotated through several hundred positions. The recorded data are processed to obtain spatially accurate estimates of the attenuation line integral and reconstructed using a cone-beam algorithm. Measurements obtained with this system are being used to study the structures found in bone biopsy specimens.<<ETX>>\",\"PeriodicalId\":447239,\"journal\":{\"name\":\"IEEE Conference on Nuclear Science Symposium and Medical Imaging\",\"volume\":\"316 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1992-10-25\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"4\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"IEEE Conference on Nuclear Science Symposium and Medical Imaging\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/NSSMIC.1992.301514\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"IEEE Conference on Nuclear Science Symposium and Medical Imaging","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/NSSMIC.1992.301514","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
An X-ray microtomography system for bone structure measurements
A system for very-high-resolution (50 mu m*50 mu m*50 mu m) three-dimensional tomography of small (1 cm*1 cm*1 cm) biological specimen is described. Two-dimensional planar X-ray views of the specimen are acquired by an image intensifier and digital camera system while the specimen is rotated through several hundred positions. The recorded data are processed to obtain spatially accurate estimates of the attenuation line integral and reconstructed using a cone-beam algorithm. Measurements obtained with this system are being used to study the structures found in bone biopsy specimens.<>