{"title":"金刚石配电网自愈系统的研究与应用","authors":"Chenhong Huang, Yuanbing Xiao, J. Lu, Huamin Yan, Mingzhu Ren, Jingde Chen","doi":"10.1109/ICPSAsia52756.2021.9621730","DOIUrl":null,"url":null,"abstract":"A self-healing system based on double-loop network connection mode is proposed in order to further improve the power supply reliability of 10kV distribution network. The model has good distributed generation(DG) access and low-carbon environmental characteristics. Firstly, this study analyzes the advantages of diamond distribution network, focuses on the structure and configuration of self-healing system. Moreover, expounds its principle from the aspects of protection action strategy, device function development and cooperation with original protection. The reliability and accuracy of the self-healing system are verified by dynamic model test and on-site joint adjustment results. Finally, as a consequence, some problems and solutions encountered in the process of installation, commissioning and operation and maintenance are summarized, which can provide some reference for the promotion and application in the future.","PeriodicalId":296085,"journal":{"name":"2021 IEEE/IAS Industrial and Commercial Power System Asia (I&CPS Asia)","volume":"6 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2021-07-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Research and Application of Diamond Distribution Network Self-Healing System\",\"authors\":\"Chenhong Huang, Yuanbing Xiao, J. Lu, Huamin Yan, Mingzhu Ren, Jingde Chen\",\"doi\":\"10.1109/ICPSAsia52756.2021.9621730\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"A self-healing system based on double-loop network connection mode is proposed in order to further improve the power supply reliability of 10kV distribution network. The model has good distributed generation(DG) access and low-carbon environmental characteristics. Firstly, this study analyzes the advantages of diamond distribution network, focuses on the structure and configuration of self-healing system. Moreover, expounds its principle from the aspects of protection action strategy, device function development and cooperation with original protection. The reliability and accuracy of the self-healing system are verified by dynamic model test and on-site joint adjustment results. Finally, as a consequence, some problems and solutions encountered in the process of installation, commissioning and operation and maintenance are summarized, which can provide some reference for the promotion and application in the future.\",\"PeriodicalId\":296085,\"journal\":{\"name\":\"2021 IEEE/IAS Industrial and Commercial Power System Asia (I&CPS Asia)\",\"volume\":\"6 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2021-07-18\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2021 IEEE/IAS Industrial and Commercial Power System Asia (I&CPS Asia)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICPSAsia52756.2021.9621730\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2021 IEEE/IAS Industrial and Commercial Power System Asia (I&CPS Asia)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICPSAsia52756.2021.9621730","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Research and Application of Diamond Distribution Network Self-Healing System
A self-healing system based on double-loop network connection mode is proposed in order to further improve the power supply reliability of 10kV distribution network. The model has good distributed generation(DG) access and low-carbon environmental characteristics. Firstly, this study analyzes the advantages of diamond distribution network, focuses on the structure and configuration of self-healing system. Moreover, expounds its principle from the aspects of protection action strategy, device function development and cooperation with original protection. The reliability and accuracy of the self-healing system are verified by dynamic model test and on-site joint adjustment results. Finally, as a consequence, some problems and solutions encountered in the process of installation, commissioning and operation and maintenance are summarized, which can provide some reference for the promotion and application in the future.