利用系统损耗和摄动参数估计状态估计中的恶意数据检测

William Niemira, R. Bobba, P. Sauer, W. Sanders
{"title":"利用系统损耗和摄动参数估计状态估计中的恶意数据检测","authors":"William Niemira, R. Bobba, P. Sauer, W. Sanders","doi":"10.1109/SmartGridComm.2013.6687991","DOIUrl":null,"url":null,"abstract":"It is critical that state estimators used in the power grid output accurate results even in the presence of erroneous measurement data. Traditional bad data detection is designed to perform well against isolated random errors. Interacting bad measurements, such as malicious data injection attacks, may be difficult to detect. In this work, we analyze the sensitivities of specific power system quantities to attacks. We compare real and reactive flow and injection measurements as potential indicators of attack. The use of parameter estimation as a means of detecting attack is also investigated. For this the state vector is augmented with known system parameters, allowing both to be estimated simultaneously. Perturbing the system topology is shown to enhance detectability through parameter estimation.","PeriodicalId":136434,"journal":{"name":"2013 IEEE International Conference on Smart Grid Communications (SmartGridComm)","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2013-12-19","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"14","resultStr":"{\"title\":\"Malicious data detection in state estimation leveraging system losses & estimation of perturbed parameters\",\"authors\":\"William Niemira, R. Bobba, P. Sauer, W. Sanders\",\"doi\":\"10.1109/SmartGridComm.2013.6687991\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"It is critical that state estimators used in the power grid output accurate results even in the presence of erroneous measurement data. Traditional bad data detection is designed to perform well against isolated random errors. Interacting bad measurements, such as malicious data injection attacks, may be difficult to detect. In this work, we analyze the sensitivities of specific power system quantities to attacks. We compare real and reactive flow and injection measurements as potential indicators of attack. The use of parameter estimation as a means of detecting attack is also investigated. For this the state vector is augmented with known system parameters, allowing both to be estimated simultaneously. Perturbing the system topology is shown to enhance detectability through parameter estimation.\",\"PeriodicalId\":136434,\"journal\":{\"name\":\"2013 IEEE International Conference on Smart Grid Communications (SmartGridComm)\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2013-12-19\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"14\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2013 IEEE International Conference on Smart Grid Communications (SmartGridComm)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/SmartGridComm.2013.6687991\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2013 IEEE International Conference on Smart Grid Communications (SmartGridComm)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/SmartGridComm.2013.6687991","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 14

摘要

在存在错误测量数据的情况下,电网中使用的状态估计器输出准确的结果是至关重要的。传统的坏数据检测被设计成能够很好地应对孤立的随机错误。交互不良度量,例如恶意数据注入攻击,可能很难检测到。在这项工作中,我们分析了特定电力系统数量对攻击的敏感性。我们比较了真实的和反应的流量和注入测量作为潜在的攻击指标。使用参数估计作为一种检测攻击的手段也进行了研究。对于这种方法,状态向量被已知的系统参数增广,允许两者同时被估计。通过参数估计,扰动系统拓扑可以增强系统的可检测性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Malicious data detection in state estimation leveraging system losses & estimation of perturbed parameters
It is critical that state estimators used in the power grid output accurate results even in the presence of erroneous measurement data. Traditional bad data detection is designed to perform well against isolated random errors. Interacting bad measurements, such as malicious data injection attacks, may be difficult to detect. In this work, we analyze the sensitivities of specific power system quantities to attacks. We compare real and reactive flow and injection measurements as potential indicators of attack. The use of parameter estimation as a means of detecting attack is also investigated. For this the state vector is augmented with known system parameters, allowing both to be estimated simultaneously. Perturbing the system topology is shown to enhance detectability through parameter estimation.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
On measurement unit placement for smart electrical grid fault localization Delay makes a difference: Smart grid resilience under remote meter disconnect attack Online energy management strategies for base stations powered by the smart grid On phasor measurement unit placement against state and topology attacks The development of a smart grid co-simulation platform and case study on Vehicle-to-Grid voltage support application
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1