无粘结柔性隔水管频域疲劳分析优化

Jiabei Yuan, Yucheng Hou, Z. Tan
{"title":"无粘结柔性隔水管频域疲劳分析优化","authors":"Jiabei Yuan, Yucheng Hou, Z. Tan","doi":"10.1115/omae2021-62886","DOIUrl":null,"url":null,"abstract":"\n Fatigue analysis of flexible risers is a demanding task in terms of time and computational resources. The traditional time domain approach may take weeks of time in global simulation, local modelling and post-processing of riser responses to get fatigue results. Baker Hughes developed a fast hybrid approach, which is based on a frequency domain technique. The new approach was first implemented at the end fitting region and then to all other regions of the riser. Studies showed that the hybrid approach achieved convenient and conservative results in a significant shorter period of time.\n To improve the accuracy and reduce conservatism of the method, Baker Hughes has further optimized the analysis procedure to seek better results approaching true solutions. Several methods were proposed and studied. The duration of representative cases and noncritical cases have been extended. The steps to predict stress spectrum based on transfer functions have also been updated. From previous studies, only one transfer function was built for fatigue load cases with similar response spectra. This assumption linearizes the system response and produces certain level of discrepancy against true time domain solution. In this study, multiple ways of spectrum prediction are evaluated and compared.\n The paper summarizes several techniques to further optimize the hybrid frequency domain approach. The updated fatigue results are found to be more accurate. The optimized approach therefore gives more flexibility to engineers to approach the true solutions, which were originally acquired from full 3-hr time domain simulations. The approach requires less analysis time and reduces iterations in pipe structure and riser configuration design, which leads to faster project execution and potential cost reduction.","PeriodicalId":240325,"journal":{"name":"Volume 4: Pipelines, Risers, and Subsea Systems","volume":"26 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2021-06-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Optimization of Frequency Domain Fatigue Analysis for Unbonded Flexible Risers\",\"authors\":\"Jiabei Yuan, Yucheng Hou, Z. Tan\",\"doi\":\"10.1115/omae2021-62886\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"\\n Fatigue analysis of flexible risers is a demanding task in terms of time and computational resources. The traditional time domain approach may take weeks of time in global simulation, local modelling and post-processing of riser responses to get fatigue results. Baker Hughes developed a fast hybrid approach, which is based on a frequency domain technique. The new approach was first implemented at the end fitting region and then to all other regions of the riser. Studies showed that the hybrid approach achieved convenient and conservative results in a significant shorter period of time.\\n To improve the accuracy and reduce conservatism of the method, Baker Hughes has further optimized the analysis procedure to seek better results approaching true solutions. Several methods were proposed and studied. The duration of representative cases and noncritical cases have been extended. The steps to predict stress spectrum based on transfer functions have also been updated. From previous studies, only one transfer function was built for fatigue load cases with similar response spectra. This assumption linearizes the system response and produces certain level of discrepancy against true time domain solution. In this study, multiple ways of spectrum prediction are evaluated and compared.\\n The paper summarizes several techniques to further optimize the hybrid frequency domain approach. The updated fatigue results are found to be more accurate. The optimized approach therefore gives more flexibility to engineers to approach the true solutions, which were originally acquired from full 3-hr time domain simulations. The approach requires less analysis time and reduces iterations in pipe structure and riser configuration design, which leads to faster project execution and potential cost reduction.\",\"PeriodicalId\":240325,\"journal\":{\"name\":\"Volume 4: Pipelines, Risers, and Subsea Systems\",\"volume\":\"26 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2021-06-21\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Volume 4: Pipelines, Risers, and Subsea Systems\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1115/omae2021-62886\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Volume 4: Pipelines, Risers, and Subsea Systems","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1115/omae2021-62886","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

柔性立管的疲劳分析在时间和计算资源方面要求很高。传统的时域方法可能需要数周的时间进行全局模拟、局部建模和隔水管响应的后处理,才能得到疲劳结果。贝克休斯开发了一种基于频域技术的快速混合方法。新方法首先在末端拟合区域实施,然后在立管的所有其他区域实施。研究表明,混合方法在较短的时间内获得了方便和保守的结果。为了提高方法的准确性和降低保守性,贝克休斯进一步优化了分析程序,寻求更接近真解的结果。提出并研究了几种方法。代表性案例和非关键案例的持续时间有所延长。基于传递函数预测应力谱的步骤也进行了更新。从以往的研究来看,对于具有相似响应谱的疲劳载荷情况,只建立了一个传递函数。这种假设使系统响应线性化,并与真实的时域解产生一定程度的差异。本研究对多种频谱预测方法进行了评价和比较。本文总结了进一步优化混合频域方法的几种技术。更新后的疲劳计算结果更为准确。因此,优化的方法为工程师提供了更大的灵活性,以接近真正的解决方案,这些解决方案最初是从完整的3小时时域模拟中获得的。该方法需要更少的分析时间,减少了管道结构和立管配置设计的迭代,从而加快了项目的执行速度,降低了潜在的成本。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Optimization of Frequency Domain Fatigue Analysis for Unbonded Flexible Risers
Fatigue analysis of flexible risers is a demanding task in terms of time and computational resources. The traditional time domain approach may take weeks of time in global simulation, local modelling and post-processing of riser responses to get fatigue results. Baker Hughes developed a fast hybrid approach, which is based on a frequency domain technique. The new approach was first implemented at the end fitting region and then to all other regions of the riser. Studies showed that the hybrid approach achieved convenient and conservative results in a significant shorter period of time. To improve the accuracy and reduce conservatism of the method, Baker Hughes has further optimized the analysis procedure to seek better results approaching true solutions. Several methods were proposed and studied. The duration of representative cases and noncritical cases have been extended. The steps to predict stress spectrum based on transfer functions have also been updated. From previous studies, only one transfer function was built for fatigue load cases with similar response spectra. This assumption linearizes the system response and produces certain level of discrepancy against true time domain solution. In this study, multiple ways of spectrum prediction are evaluated and compared. The paper summarizes several techniques to further optimize the hybrid frequency domain approach. The updated fatigue results are found to be more accurate. The optimized approach therefore gives more flexibility to engineers to approach the true solutions, which were originally acquired from full 3-hr time domain simulations. The approach requires less analysis time and reduces iterations in pipe structure and riser configuration design, which leads to faster project execution and potential cost reduction.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Integrity Monitoring of Offshore Arctic Pipelines Investigation of Near-Field Temperature Distribution in Buried Dense Phase CO2 Pipelines On the Plastic Bending Responses of Dented Lined Pipe Implementation of a Method for Free-Spanning Pipeline Analysis Simplified Stochastic Modelling of the Force on a Pipe Bend Due to Two-Phase Slug Flow
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1