{"title":"有维修80mva立式水轮发电机定子铁芯严重故障的经验","authors":"S. Bomben, B. Pratt","doi":"10.1109/EEIC.2005.1566260","DOIUrl":null,"url":null,"abstract":"The unexpected failure of an 80 MVA hydro generator seriously damaged the stator core. A river system with high water left few options for repair. Aggressive methods were used to return the unit back to service while a new core section was delivered to site","PeriodicalId":267510,"journal":{"name":"Proceedings Electrical Insulation Conference and Electrical Manufacturing Expo, 2005.","volume":"39 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1900-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":"{\"title\":\"Experience repairing a serious stator core fault on an 80 MVA vertical water wheel generator\",\"authors\":\"S. Bomben, B. Pratt\",\"doi\":\"10.1109/EEIC.2005.1566260\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The unexpected failure of an 80 MVA hydro generator seriously damaged the stator core. A river system with high water left few options for repair. Aggressive methods were used to return the unit back to service while a new core section was delivered to site\",\"PeriodicalId\":267510,\"journal\":{\"name\":\"Proceedings Electrical Insulation Conference and Electrical Manufacturing Expo, 2005.\",\"volume\":\"39 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1900-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"3\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Proceedings Electrical Insulation Conference and Electrical Manufacturing Expo, 2005.\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/EEIC.2005.1566260\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings Electrical Insulation Conference and Electrical Manufacturing Expo, 2005.","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/EEIC.2005.1566260","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Experience repairing a serious stator core fault on an 80 MVA vertical water wheel generator
The unexpected failure of an 80 MVA hydro generator seriously damaged the stator core. A river system with high water left few options for repair. Aggressive methods were used to return the unit back to service while a new core section was delivered to site