静音发电箱空气温度控制系统

Anif Saukon Kamalul Husna, D. Desriyanti, Rhesma Intan Vidyastari
{"title":"静音发电箱空气温度控制系统","authors":"Anif Saukon Kamalul Husna, D. Desriyanti, Rhesma Intan Vidyastari","doi":"10.21070/jeeeu.v5i2.1556","DOIUrl":null,"url":null,"abstract":"For the community, generators are an alternative if there is a power outage or if there is a large enough electricity demand. According to workers in the field of generator rental in Trenggalek, namely \"db Genset\" which has the address Ds. Gondang, Kec. Tugu, Kab. Trenggalek, there are 2 types of generators, namely open generators and silent generators, and most people choose silent generators because silent generators are specially designed to muffle engine noise so they don't cause noise, very suitable for use in active environments, but silent generators often experience temperature problems rise (Overheating) which is due to a closed engine and less smooth air circulation. Thus the cooling system on the generator set is needed to support the safety of the temperature on the silent generator so that it remains normal below 70°C which is important to minimize overheating problems in the silent generator, so that it can improve the performance of the generator to work for a long time without any problems. overheating. The design of the Temperature Control System in this Silent Genset Box uses Arduino Uno as a system controller and uses the Ds18b20 sensor, the engine temperature cooling process previously relied on radiator water and radiator fans, so the idea arose to add blower fans on both sides of the silent generator box, marked with a green temperature light indicator. being below 70°C indicates the temperature inside the box is normal, the blue light indicator indicates the temperature inside the box is in the 70°C to 95°C temperature range, fan 1 is on, the red light indicator indicates the temperature in the box is in the 95°C to 120°C temperature range, fans 1 and 2 are on, and the red light indicator indicates the temperature in the box is in the temperature range of 95°C to 120°C if the temperature reaches 120°C the generator engine will turn off indicating the temperature in the box maxsimal fan 1 and 2 remain on until the temperature decreases to 40°C, and every change in temperature will send a notification via SMS to the generator operator","PeriodicalId":320287,"journal":{"name":"JEEE-U (Journal of Electrical and Electronic Engineering-UMSIDA)","volume":"811 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2021-10-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Air Temperature Control System In Silent Generator Box\",\"authors\":\"Anif Saukon Kamalul Husna, D. Desriyanti, Rhesma Intan Vidyastari\",\"doi\":\"10.21070/jeeeu.v5i2.1556\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"For the community, generators are an alternative if there is a power outage or if there is a large enough electricity demand. According to workers in the field of generator rental in Trenggalek, namely \\\"db Genset\\\" which has the address Ds. Gondang, Kec. Tugu, Kab. Trenggalek, there are 2 types of generators, namely open generators and silent generators, and most people choose silent generators because silent generators are specially designed to muffle engine noise so they don't cause noise, very suitable for use in active environments, but silent generators often experience temperature problems rise (Overheating) which is due to a closed engine and less smooth air circulation. Thus the cooling system on the generator set is needed to support the safety of the temperature on the silent generator so that it remains normal below 70°C which is important to minimize overheating problems in the silent generator, so that it can improve the performance of the generator to work for a long time without any problems. overheating. The design of the Temperature Control System in this Silent Genset Box uses Arduino Uno as a system controller and uses the Ds18b20 sensor, the engine temperature cooling process previously relied on radiator water and radiator fans, so the idea arose to add blower fans on both sides of the silent generator box, marked with a green temperature light indicator. being below 70°C indicates the temperature inside the box is normal, the blue light indicator indicates the temperature inside the box is in the 70°C to 95°C temperature range, fan 1 is on, the red light indicator indicates the temperature in the box is in the 95°C to 120°C temperature range, fans 1 and 2 are on, and the red light indicator indicates the temperature in the box is in the temperature range of 95°C to 120°C if the temperature reaches 120°C the generator engine will turn off indicating the temperature in the box maxsimal fan 1 and 2 remain on until the temperature decreases to 40°C, and every change in temperature will send a notification via SMS to the generator operator\",\"PeriodicalId\":320287,\"journal\":{\"name\":\"JEEE-U (Journal of Electrical and Electronic Engineering-UMSIDA)\",\"volume\":\"811 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2021-10-05\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"JEEE-U (Journal of Electrical and Electronic Engineering-UMSIDA)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.21070/jeeeu.v5i2.1556\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"JEEE-U (Journal of Electrical and Electronic Engineering-UMSIDA)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.21070/jeeeu.v5i2.1556","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

对于社区来说,如果停电或电力需求足够大,发电机是另一种选择。据Trenggalek发电机租赁领域的工作人员介绍,即地址为d的“db Genset”。Gondang, Kec。Tugu,出租车。Trenggalek,有两种类型的发电机,即开放式发电机和静音发电机,大多数人选择静音发电机,因为静音发电机是专门设计来消音发动机的噪音,所以他们不会产生噪音,非常适合在活跃的环境中使用,但静音发电机经常遇到温度上升(过热)的问题,这是由于一个封闭的发动机和不太顺畅的空气循环。因此,发电机组上的冷却系统需要支持静音发电机上的温度安全,使其在70°C以下保持正常,这对于减少静音发电机的过热问题非常重要,从而可以提高发电机的性能,使其长时间工作而没有任何问题。过热。这款静音发电箱的温控系统设计采用Arduino Uno作为系统控制器,采用Ds18b20传感器,发动机温度冷却过程之前依赖于散热器水和散热器风扇,因此产生了在静音发电箱两侧增加鼓风机的想法,并以绿色温度指示灯标记。当低于70℃时,表示盒内温度正常,蓝灯指示盒内温度在70℃~ 95℃范围内,风扇1亮,红灯指示盒内温度在95℃~ 120℃范围内,风扇1、2亮。红灯指示箱内温度在95℃~ 120℃范围内,当温度达到120℃时,发电机发动机关闭,指示箱内温度最大风扇1和2保持打开,直到温度降至40℃,每次温度变化都会通过短信通知发电机操作员
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Air Temperature Control System In Silent Generator Box
For the community, generators are an alternative if there is a power outage or if there is a large enough electricity demand. According to workers in the field of generator rental in Trenggalek, namely "db Genset" which has the address Ds. Gondang, Kec. Tugu, Kab. Trenggalek, there are 2 types of generators, namely open generators and silent generators, and most people choose silent generators because silent generators are specially designed to muffle engine noise so they don't cause noise, very suitable for use in active environments, but silent generators often experience temperature problems rise (Overheating) which is due to a closed engine and less smooth air circulation. Thus the cooling system on the generator set is needed to support the safety of the temperature on the silent generator so that it remains normal below 70°C which is important to minimize overheating problems in the silent generator, so that it can improve the performance of the generator to work for a long time without any problems. overheating. The design of the Temperature Control System in this Silent Genset Box uses Arduino Uno as a system controller and uses the Ds18b20 sensor, the engine temperature cooling process previously relied on radiator water and radiator fans, so the idea arose to add blower fans on both sides of the silent generator box, marked with a green temperature light indicator. being below 70°C indicates the temperature inside the box is normal, the blue light indicator indicates the temperature inside the box is in the 70°C to 95°C temperature range, fan 1 is on, the red light indicator indicates the temperature in the box is in the 95°C to 120°C temperature range, fans 1 and 2 are on, and the red light indicator indicates the temperature in the box is in the temperature range of 95°C to 120°C if the temperature reaches 120°C the generator engine will turn off indicating the temperature in the box maxsimal fan 1 and 2 remain on until the temperature decreases to 40°C, and every change in temperature will send a notification via SMS to the generator operator
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Leak Monitoring in Split Duct Air Conditioner Based on Internet of Things Design of a Height and Weight Measurement Tool for Toddlers at Spreadsheet-Based Posyandu The Protection Relay Coordination Studies (Over Current Relays and Ground Fault Relays) On The Power Plant Electrical System, PT. Rekind Daya Mamuju By Using The ETAP 12.6 Program Design of Atmega2560 Charge Controller Battery Using Static Bicycle Sistem Monitoring Dan Kontrol Motor Listrik Industri Menggunakan Internet Of Things (IoT)
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1