{"title":"SAW气体传感与气体浓度的关系研究","authors":"I. V. Anisimkin, V. Anisimkin, C. Caliendo, E. Verona, M. Penza","doi":"10.1109/ULTSYM.1999.849445","DOIUrl":null,"url":null,"abstract":"An analytical expression for the SAW sensor gas response versus gas concentration (calibration curve) is deduced, at low gas concentrations, on using the perturbation approach. The calibration curve, the sensitivity (its slope) and the detection limit (threshold value) for a given gas and sorbent membrane, can be controlled by a proper choice of the substrate material and its crystallographic orientation. We show how this property takes place from the anisotropy of the SAW propagation on piezoelectric single crystals, allowing to change the partial contributions to the SAW response through mechanical displacements, coupling constant and temperature coefficient of velocity (TCV). The theoretical predictions are experimentally verified on devices implemented on different orientations of quartz and LiNbO3 substrates, using Pd, Pd:Ni and polyvinyl alcohol (PVA) as sorbent films and humid air as analyte. The lowest threshold value of RH (0.01%) and the highest sensitivity (49 ppm/%) are detected in the PVA/yz-LiNbO3 structure, whose sensitivity is about two orders of magnitude higher than that observed in uncoated LiNbO3.","PeriodicalId":339424,"journal":{"name":"1999 IEEE Ultrasonics Symposium. Proceedings. International Symposium (Cat. No.99CH37027)","volume":"140 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1999-10-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"7","resultStr":"{\"title\":\"A study of SAW gas sensing versus gas concentration\",\"authors\":\"I. V. Anisimkin, V. Anisimkin, C. Caliendo, E. Verona, M. Penza\",\"doi\":\"10.1109/ULTSYM.1999.849445\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"An analytical expression for the SAW sensor gas response versus gas concentration (calibration curve) is deduced, at low gas concentrations, on using the perturbation approach. The calibration curve, the sensitivity (its slope) and the detection limit (threshold value) for a given gas and sorbent membrane, can be controlled by a proper choice of the substrate material and its crystallographic orientation. We show how this property takes place from the anisotropy of the SAW propagation on piezoelectric single crystals, allowing to change the partial contributions to the SAW response through mechanical displacements, coupling constant and temperature coefficient of velocity (TCV). The theoretical predictions are experimentally verified on devices implemented on different orientations of quartz and LiNbO3 substrates, using Pd, Pd:Ni and polyvinyl alcohol (PVA) as sorbent films and humid air as analyte. The lowest threshold value of RH (0.01%) and the highest sensitivity (49 ppm/%) are detected in the PVA/yz-LiNbO3 structure, whose sensitivity is about two orders of magnitude higher than that observed in uncoated LiNbO3.\",\"PeriodicalId\":339424,\"journal\":{\"name\":\"1999 IEEE Ultrasonics Symposium. Proceedings. International Symposium (Cat. No.99CH37027)\",\"volume\":\"140 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1999-10-17\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"7\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"1999 IEEE Ultrasonics Symposium. Proceedings. International Symposium (Cat. No.99CH37027)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ULTSYM.1999.849445\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"1999 IEEE Ultrasonics Symposium. Proceedings. International Symposium (Cat. No.99CH37027)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ULTSYM.1999.849445","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 7

摘要

在低气体浓度条件下,利用微扰方法推导出SAW传感器气体响应随气体浓度变化的解析表达式(校准曲线)。对给定气体和吸附膜的校准曲线、灵敏度(其斜率)和检测限(阈值)可以通过适当选择衬底材料及其晶体取向来控制。我们展示了这种特性是如何从压电单晶上SAW传播的各向异性中发生的,允许通过机械位移,耦合常数和速度温度系数(TCV)改变SAW响应的部分贡献。在不同取向的石英和LiNbO3衬底上,以Pd、Pd:Ni和聚乙烯醇(PVA)为吸附膜,以潮湿空气为分析物,实验验证了理论预测。在PVA/yz-LiNbO3结构中检测到最低的RH阈值(0.01%)和最高的灵敏度(49 ppm/%),其灵敏度比未涂覆的LiNbO3高约两个数量级。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
A study of SAW gas sensing versus gas concentration
An analytical expression for the SAW sensor gas response versus gas concentration (calibration curve) is deduced, at low gas concentrations, on using the perturbation approach. The calibration curve, the sensitivity (its slope) and the detection limit (threshold value) for a given gas and sorbent membrane, can be controlled by a proper choice of the substrate material and its crystallographic orientation. We show how this property takes place from the anisotropy of the SAW propagation on piezoelectric single crystals, allowing to change the partial contributions to the SAW response through mechanical displacements, coupling constant and temperature coefficient of velocity (TCV). The theoretical predictions are experimentally verified on devices implemented on different orientations of quartz and LiNbO3 substrates, using Pd, Pd:Ni and polyvinyl alcohol (PVA) as sorbent films and humid air as analyte. The lowest threshold value of RH (0.01%) and the highest sensitivity (49 ppm/%) are detected in the PVA/yz-LiNbO3 structure, whose sensitivity is about two orders of magnitude higher than that observed in uncoated LiNbO3.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Fast beam shape computation and wave propagation via the Radon transform Experimental verification of acoustic saturation Ultrasonic characterization of emulsions: milk and water in oil High-contrast RF correlation imaging of defects in food package seals Analysis of resolution for an amplitude steered array
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1