{"title":"用于糖尿病患者即时检测的便携式分光光度计呼气分析仪","authors":"Nicole M. Banach, M. Rust, R. Priefer","doi":"10.1109/NEBEC.2013.44","DOIUrl":null,"url":null,"abstract":"Diabetes Mellitus is a metabolic disorder characterized by the lack of sufficient insulin. This disease has become a national epidemic in the United States, and therapy non-adherence has become one of the largest precursors leading to diabetic sequelae such as diabetic ketoacidosis. A potential source of patient therapy negligence is the discomfort associated with the finger prick method of glucose monitoring. As a result, a less invasive method to monitor diabetes is sought. This paper describes a portable breathalyzer that is being developed to monitor acetone in the breath of a diabetic patient. The proposed design aims to eliminate the finger prick through a simplified approach for monitoring acetone levels in correlation to elevated glucose levels, thus determining the onset of diabetic ketoacidosis.","PeriodicalId":153112,"journal":{"name":"2013 39th Annual Northeast Bioengineering Conference","volume":"155 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2013-04-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"5","resultStr":"{\"title\":\"A Portable Spectrophotometer-Based Breathalyzer for Point-of-Care Testing of Diabetic Patients\",\"authors\":\"Nicole M. Banach, M. Rust, R. Priefer\",\"doi\":\"10.1109/NEBEC.2013.44\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Diabetes Mellitus is a metabolic disorder characterized by the lack of sufficient insulin. This disease has become a national epidemic in the United States, and therapy non-adherence has become one of the largest precursors leading to diabetic sequelae such as diabetic ketoacidosis. A potential source of patient therapy negligence is the discomfort associated with the finger prick method of glucose monitoring. As a result, a less invasive method to monitor diabetes is sought. This paper describes a portable breathalyzer that is being developed to monitor acetone in the breath of a diabetic patient. The proposed design aims to eliminate the finger prick through a simplified approach for monitoring acetone levels in correlation to elevated glucose levels, thus determining the onset of diabetic ketoacidosis.\",\"PeriodicalId\":153112,\"journal\":{\"name\":\"2013 39th Annual Northeast Bioengineering Conference\",\"volume\":\"155 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2013-04-05\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"5\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2013 39th Annual Northeast Bioengineering Conference\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/NEBEC.2013.44\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2013 39th Annual Northeast Bioengineering Conference","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/NEBEC.2013.44","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
A Portable Spectrophotometer-Based Breathalyzer for Point-of-Care Testing of Diabetic Patients
Diabetes Mellitus is a metabolic disorder characterized by the lack of sufficient insulin. This disease has become a national epidemic in the United States, and therapy non-adherence has become one of the largest precursors leading to diabetic sequelae such as diabetic ketoacidosis. A potential source of patient therapy negligence is the discomfort associated with the finger prick method of glucose monitoring. As a result, a less invasive method to monitor diabetes is sought. This paper describes a portable breathalyzer that is being developed to monitor acetone in the breath of a diabetic patient. The proposed design aims to eliminate the finger prick through a simplified approach for monitoring acetone levels in correlation to elevated glucose levels, thus determining the onset of diabetic ketoacidosis.