并网光伏系统不平衡故障分析

Listhianne Willy Anak Badi, Z. Zakaria, A. H. M. Nordin, R. F. Mustapa
{"title":"并网光伏系统不平衡故障分析","authors":"Listhianne Willy Anak Badi, Z. Zakaria, A. H. M. Nordin, R. F. Mustapa","doi":"10.1109/PECON.2014.7062471","DOIUrl":null,"url":null,"abstract":"A search for replacement of non-renewable energy leads to a new founding that is renewable energy which is unlimited energy source. One of the renewable energy is solar energy where photovoltaic (PV) array is used to convert the energy from the sun to electrical energy. PV is widely use in the grid-connected system nowadays. Since the founding of this method, the technology of extracting solar energy from photovoltaic array into grid network system has been growing rapidly. However, with the best installation method the photovoltaic system could not guarantee the system is immune to fault and its effects. The existence of fault in the grid system may cause a drop in the outputs and will drop even lower with penetration of photovoltaic devices in the system. This paper presents the effects of faults penetration inside the grid-connected PV system with three unbalanced faults being tested for this purpose and compare the results obtained. To observe the effects of these faults, a model of grid-connected PV system is built using MATLAB® 2009/Simulink with the help of Simscape and SimPowerSystems toolboxes. First, a PV system is developed in order to make the photovoltaic sourcing the system using a solar cell lumped with 70 others cell to make a PV module. With the help of a booster, the PV system voltage output is regulated and linked to a three-phase inverter circuit. Step-up transformers then are placed at the end of the inverter to replicate real-life utility. Lastly, faults are injected to the connection of inverter and the second transformer of the end of the system is observed for any changes in the voltage magnitude and waveform.","PeriodicalId":126366,"journal":{"name":"2014 IEEE International Conference on Power and Energy (PECon)","volume":"487 1-2 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2014-03-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"9","resultStr":"{\"title\":\"Unbalanced faults analysis in grid - Connected PV system\",\"authors\":\"Listhianne Willy Anak Badi, Z. Zakaria, A. H. M. Nordin, R. F. Mustapa\",\"doi\":\"10.1109/PECON.2014.7062471\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"A search for replacement of non-renewable energy leads to a new founding that is renewable energy which is unlimited energy source. One of the renewable energy is solar energy where photovoltaic (PV) array is used to convert the energy from the sun to electrical energy. PV is widely use in the grid-connected system nowadays. Since the founding of this method, the technology of extracting solar energy from photovoltaic array into grid network system has been growing rapidly. However, with the best installation method the photovoltaic system could not guarantee the system is immune to fault and its effects. The existence of fault in the grid system may cause a drop in the outputs and will drop even lower with penetration of photovoltaic devices in the system. This paper presents the effects of faults penetration inside the grid-connected PV system with three unbalanced faults being tested for this purpose and compare the results obtained. To observe the effects of these faults, a model of grid-connected PV system is built using MATLAB® 2009/Simulink with the help of Simscape and SimPowerSystems toolboxes. First, a PV system is developed in order to make the photovoltaic sourcing the system using a solar cell lumped with 70 others cell to make a PV module. With the help of a booster, the PV system voltage output is regulated and linked to a three-phase inverter circuit. Step-up transformers then are placed at the end of the inverter to replicate real-life utility. Lastly, faults are injected to the connection of inverter and the second transformer of the end of the system is observed for any changes in the voltage magnitude and waveform.\",\"PeriodicalId\":126366,\"journal\":{\"name\":\"2014 IEEE International Conference on Power and Energy (PECon)\",\"volume\":\"487 1-2 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2014-03-17\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"9\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2014 IEEE International Conference on Power and Energy (PECon)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/PECON.2014.7062471\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2014 IEEE International Conference on Power and Energy (PECon)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/PECON.2014.7062471","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 9

摘要

寻找替代不可再生能源的方法导致了一种新的发现,即可再生能源是无限的能源。其中一种可再生能源是太阳能,利用光伏(PV)阵列将太阳能转化为电能。光伏发电在并网系统中得到了广泛的应用。自该方法建立以来,从光伏阵列中提取太阳能并网系统的技术得到了迅速发展。然而,即使采用最佳的安装方式,光伏系统也不能保证系统不受故障及其影响。电网系统中故障的存在可能会导致输出下降,随着光伏设备在系统中的渗透,输出下降会更低。本文介绍了故障对并网光伏系统内部渗透的影响,并为此对三个不平衡故障进行了测试,并对结果进行了比较。为了观察这些故障的影响,利用MATLAB®2009/Simulink,借助Simscape和SimPowerSystems工具箱,建立了并网光伏系统的模型。首先,开发了一个光伏系统,以使光伏源系统使用一个太阳能电池与其他70个电池集成一个光伏模块。在升压器的帮助下,光伏系统电压输出被调节并连接到三相逆变电路。升压变压器然后被放置在逆变器的末端,以复制现实生活中的效用。最后,将故障注入逆变器连接处,观察系统末端的第二台变压器电压幅值和波形是否有变化。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Unbalanced faults analysis in grid - Connected PV system
A search for replacement of non-renewable energy leads to a new founding that is renewable energy which is unlimited energy source. One of the renewable energy is solar energy where photovoltaic (PV) array is used to convert the energy from the sun to electrical energy. PV is widely use in the grid-connected system nowadays. Since the founding of this method, the technology of extracting solar energy from photovoltaic array into grid network system has been growing rapidly. However, with the best installation method the photovoltaic system could not guarantee the system is immune to fault and its effects. The existence of fault in the grid system may cause a drop in the outputs and will drop even lower with penetration of photovoltaic devices in the system. This paper presents the effects of faults penetration inside the grid-connected PV system with three unbalanced faults being tested for this purpose and compare the results obtained. To observe the effects of these faults, a model of grid-connected PV system is built using MATLAB® 2009/Simulink with the help of Simscape and SimPowerSystems toolboxes. First, a PV system is developed in order to make the photovoltaic sourcing the system using a solar cell lumped with 70 others cell to make a PV module. With the help of a booster, the PV system voltage output is regulated and linked to a three-phase inverter circuit. Step-up transformers then are placed at the end of the inverter to replicate real-life utility. Lastly, faults are injected to the connection of inverter and the second transformer of the end of the system is observed for any changes in the voltage magnitude and waveform.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Modeling of polymer nanocomposites: Permittivity vs. electric field intensity Techno-economical assessment of grid-connected photovoltaic power systems productivity in summer season in Klagenfurt, Austria Effect of fault resistance on the behavior of superconducting fault current limiter in power systems A case study on ground resistance based on copper electrode vs. galvanized iron electrode Flashover monitoring system using wireless sensor network
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1