{"title":"自激感应发电机的相位平衡","authors":"T. Chan, L. Lai","doi":"10.1109/DRPT.2000.855734","DOIUrl":null,"url":null,"abstract":"This paper describes a phase-balancing scheme for a three-phase self-excited induction generator (SEIG) which supplies single-phase loads. It is demonstrated that perfect phase balance can be achieved using a modified Steinmetz connection, provided that the positive-sequence impedance angle of the SEIG exceeds 2/spl pi//3 rad. From the phasor diagram, the conditions for perfect balance are established. It is found that the values of phase converter elements as well as the load resistance are functions of the positive-sequence admittance and impedance angle of the induction generator. Using the method of symmetrical components, the input impedance of the SEIG can be determined and solution of the equivalent circuit is formulated as a function minimization problem. The pattern search method of Hooke and Jeeves is employed for minimizing the impedance function, which enables the machine variables to be determined. It is further shown that, when the auxiliary load resistance is absent, perfect phase balance can still be achieved when the impedance angle of the SEIG is equal to 2/spl pi//3 rad. Feasibility of the phase-balancing schemes and the validity of the theoretical analysis are confirmed by experiments on a 2.2 kW induction machine.","PeriodicalId":127287,"journal":{"name":"DRPT2000. International Conference on Electric Utility Deregulation and Restructuring and Power Technologies. Proceedings (Cat. No.00EX382)","volume":"55 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2000-04-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"6","resultStr":"{\"title\":\"Phase balancing for a self-excited induction generator\",\"authors\":\"T. Chan, L. Lai\",\"doi\":\"10.1109/DRPT.2000.855734\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper describes a phase-balancing scheme for a three-phase self-excited induction generator (SEIG) which supplies single-phase loads. It is demonstrated that perfect phase balance can be achieved using a modified Steinmetz connection, provided that the positive-sequence impedance angle of the SEIG exceeds 2/spl pi//3 rad. From the phasor diagram, the conditions for perfect balance are established. It is found that the values of phase converter elements as well as the load resistance are functions of the positive-sequence admittance and impedance angle of the induction generator. Using the method of symmetrical components, the input impedance of the SEIG can be determined and solution of the equivalent circuit is formulated as a function minimization problem. The pattern search method of Hooke and Jeeves is employed for minimizing the impedance function, which enables the machine variables to be determined. It is further shown that, when the auxiliary load resistance is absent, perfect phase balance can still be achieved when the impedance angle of the SEIG is equal to 2/spl pi//3 rad. Feasibility of the phase-balancing schemes and the validity of the theoretical analysis are confirmed by experiments on a 2.2 kW induction machine.\",\"PeriodicalId\":127287,\"journal\":{\"name\":\"DRPT2000. International Conference on Electric Utility Deregulation and Restructuring and Power Technologies. Proceedings (Cat. No.00EX382)\",\"volume\":\"55 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2000-04-04\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"6\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"DRPT2000. International Conference on Electric Utility Deregulation and Restructuring and Power Technologies. Proceedings (Cat. No.00EX382)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/DRPT.2000.855734\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"DRPT2000. International Conference on Electric Utility Deregulation and Restructuring and Power Technologies. Proceedings (Cat. No.00EX382)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/DRPT.2000.855734","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 6

摘要

本文介绍了单相负载供电的三相自激感应发电机(SEIG)的相位平衡方案。结果表明,当SEIG的正序阻抗角大于2/spl pi//3 rad时,采用改进的Steinmetz连接可以实现完全相位平衡,并从相量图中建立了完全平衡的条件。结果表明,变相元件的值和负载电阻是感应发电机正序导纳和阻抗角的函数。利用对称分量法,可以确定等效电路的输入阻抗,并将等效电路的求解公式化为函数最小化问题。采用Hooke和Jeeves的模式搜索方法对阻抗函数进行最小化,从而确定机器变量。进一步表明,当辅助负载电阻不存在时,当SEIG的阻抗角等于2/spl pi//3 rad时,仍然可以实现完美的相位平衡。通过在2.2 kW感应电机上的实验,验证了相平衡方案的可行性和理论分析的有效性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Phase balancing for a self-excited induction generator
This paper describes a phase-balancing scheme for a three-phase self-excited induction generator (SEIG) which supplies single-phase loads. It is demonstrated that perfect phase balance can be achieved using a modified Steinmetz connection, provided that the positive-sequence impedance angle of the SEIG exceeds 2/spl pi//3 rad. From the phasor diagram, the conditions for perfect balance are established. It is found that the values of phase converter elements as well as the load resistance are functions of the positive-sequence admittance and impedance angle of the induction generator. Using the method of symmetrical components, the input impedance of the SEIG can be determined and solution of the equivalent circuit is formulated as a function minimization problem. The pattern search method of Hooke and Jeeves is employed for minimizing the impedance function, which enables the machine variables to be determined. It is further shown that, when the auxiliary load resistance is absent, perfect phase balance can still be achieved when the impedance angle of the SEIG is equal to 2/spl pi//3 rad. Feasibility of the phase-balancing schemes and the validity of the theoretical analysis are confirmed by experiments on a 2.2 kW induction machine.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Degeneracy and duality gap on optimization-based electricity auctions Evaluation of the Romanian electricity industry restructuring process in comparison with the experience in the United Kingdom The use of tangent vectors for voltage collapse analysis Study of interrelations between electric power systems and large consumers in Russia Short-term investment scheduling in transmission power systems by evolutionary computation
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1