减小STATCOM直流母线电压失真的影响

B. Blazic, I. Papič
{"title":"减小STATCOM直流母线电压失真的影响","authors":"B. Blazic, I. Papič","doi":"10.1109/MELCON.2004.1348248","DOIUrl":null,"url":null,"abstract":"This paper proposes a control technique for minimizing the effect of a distorted DC-bus voltage on the operation of a PWM controlled STATCOM. A DC-bus voltage ripple occurs as a consequence of harmonic or unbalanced currents exchange between the compensator and the network and causes additional harmonic distortion on the AC side, which is not permissible for compensator operation. The proposed DC-ripple mitigation technique is based on the modulation of the switching function enabling the device operation with distorted DC-bus voltage and allowing the use of a relatively small capacitor on the DC side. The derived control algorithm is validated by means of digital simulation in the PSCAD/EMTDC program where a case of a STATCOM operating under unbalanced conditions (unbalanced network voltage) was evaluated.","PeriodicalId":164818,"journal":{"name":"Proceedings of the 12th IEEE Mediterranean Electrotechnical Conference (IEEE Cat. No.04CH37521)","volume":"470 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2004-05-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"4","resultStr":"{\"title\":\"Minimizing the effect of a distorted DC-bus voltage of a STATCOM\",\"authors\":\"B. Blazic, I. Papič\",\"doi\":\"10.1109/MELCON.2004.1348248\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper proposes a control technique for minimizing the effect of a distorted DC-bus voltage on the operation of a PWM controlled STATCOM. A DC-bus voltage ripple occurs as a consequence of harmonic or unbalanced currents exchange between the compensator and the network and causes additional harmonic distortion on the AC side, which is not permissible for compensator operation. The proposed DC-ripple mitigation technique is based on the modulation of the switching function enabling the device operation with distorted DC-bus voltage and allowing the use of a relatively small capacitor on the DC side. The derived control algorithm is validated by means of digital simulation in the PSCAD/EMTDC program where a case of a STATCOM operating under unbalanced conditions (unbalanced network voltage) was evaluated.\",\"PeriodicalId\":164818,\"journal\":{\"name\":\"Proceedings of the 12th IEEE Mediterranean Electrotechnical Conference (IEEE Cat. No.04CH37521)\",\"volume\":\"470 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2004-05-12\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"4\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Proceedings of the 12th IEEE Mediterranean Electrotechnical Conference (IEEE Cat. No.04CH37521)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/MELCON.2004.1348248\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings of the 12th IEEE Mediterranean Electrotechnical Conference (IEEE Cat. No.04CH37521)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/MELCON.2004.1348248","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 4

摘要

本文提出了一种减小直流母线畸变电压对PWM控制的STATCOM工作影响的控制技术。直流母线电压纹波是补偿器和网络之间的谐波或不平衡电流交换的结果,并在交流侧引起额外的谐波失真,这是不允许补偿器运行的。所提出的直流纹波缓解技术是基于开关功能的调制,使器件能够在扭曲的直流母线电压下工作,并允许在直流侧使用相对较小的电容器。通过PSCAD/EMTDC程序的数字仿真验证了所推导的控制算法,并对STATCOM在不平衡条件下(不平衡网络电压)工作的情况进行了评估。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Minimizing the effect of a distorted DC-bus voltage of a STATCOM
This paper proposes a control technique for minimizing the effect of a distorted DC-bus voltage on the operation of a PWM controlled STATCOM. A DC-bus voltage ripple occurs as a consequence of harmonic or unbalanced currents exchange between the compensator and the network and causes additional harmonic distortion on the AC side, which is not permissible for compensator operation. The proposed DC-ripple mitigation technique is based on the modulation of the switching function enabling the device operation with distorted DC-bus voltage and allowing the use of a relatively small capacitor on the DC side. The derived control algorithm is validated by means of digital simulation in the PSCAD/EMTDC program where a case of a STATCOM operating under unbalanced conditions (unbalanced network voltage) was evaluated.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Virtual restoration of fragmented glass plate photographs Multirate decorrelating detector for UMTS Experimental comparison of substrate structures for inductors and transformers Illegal connection location on main power cable Formal verification of ad-hoc routing protocols using SPIN model checker
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1