{"title":"直流电场对双电线火焰蔓延的影响","authors":"Jeong Park, S. H. Park, M. Cha, S. Chung","doi":"10.1115/ajkfluids2019-4693","DOIUrl":null,"url":null,"abstract":"\n The effect of DC electric field on the behaviors of spreading flame over polyethylene (PE)-insulated twin electrical wires was investigated by varying the wire gap (S) and voltage (VDC). The twin flame spreads with the same flame spread rate (FSR) independently when no electric field is applied. With an applied DC electric field, the twin flame interacts such that FSR, flame width, and the leaning direction of interacting twin flames vary appreciably. The spread rate for wire flame with negative voltage (SF–) was larger than that with positive voltage (SF+) during transient period and then the two became the same in a developed region (a quasi-steady spread). Such a flame behavior could be grouped into two: twin flame spread (regime I) and single flame spread (regime II) after the extinction of SF+. Each regime could be categorized into three sub-regimes depending on S and VDC. For small VDC, the flame leaned toward the burnt wire, reducing FSR. With further increasing VDC, FSR increased due to the ionic wind effect and then decreased via the mass loss of molten PE. These non-monotonic behavior of FSR with DC voltage can be attributed the behaviors of molten PE, exhibiting dripping, electrospray, and di-electrophoresis phenomena. For further increased voltage, the flames were extinguished by streamer generation and an electrical short occurred at excessive voltages.","PeriodicalId":403423,"journal":{"name":"Volume 3A: Fluid Applications and Systems","volume":"2 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2019-11-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Effect of DC Electric Fields on Flame Spread Over Twin Electrical Wires\",\"authors\":\"Jeong Park, S. H. Park, M. Cha, S. Chung\",\"doi\":\"10.1115/ajkfluids2019-4693\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"\\n The effect of DC electric field on the behaviors of spreading flame over polyethylene (PE)-insulated twin electrical wires was investigated by varying the wire gap (S) and voltage (VDC). The twin flame spreads with the same flame spread rate (FSR) independently when no electric field is applied. With an applied DC electric field, the twin flame interacts such that FSR, flame width, and the leaning direction of interacting twin flames vary appreciably. The spread rate for wire flame with negative voltage (SF–) was larger than that with positive voltage (SF+) during transient period and then the two became the same in a developed region (a quasi-steady spread). Such a flame behavior could be grouped into two: twin flame spread (regime I) and single flame spread (regime II) after the extinction of SF+. Each regime could be categorized into three sub-regimes depending on S and VDC. For small VDC, the flame leaned toward the burnt wire, reducing FSR. With further increasing VDC, FSR increased due to the ionic wind effect and then decreased via the mass loss of molten PE. These non-monotonic behavior of FSR with DC voltage can be attributed the behaviors of molten PE, exhibiting dripping, electrospray, and di-electrophoresis phenomena. For further increased voltage, the flames were extinguished by streamer generation and an electrical short occurred at excessive voltages.\",\"PeriodicalId\":403423,\"journal\":{\"name\":\"Volume 3A: Fluid Applications and Systems\",\"volume\":\"2 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2019-11-20\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Volume 3A: Fluid Applications and Systems\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1115/ajkfluids2019-4693\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Volume 3A: Fluid Applications and Systems","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1115/ajkfluids2019-4693","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

通过改变线隙(S)和电压(VDC),研究了直流电场对聚乙烯(PE)绝缘双导线上火焰蔓延行为的影响。在无电场作用下,双火焰以相同的火焰蔓延速率(FSR)独立传播。在施加直流电场的情况下,双火焰相互作用,使FSR、火焰宽度和相互作用的双火焰的倾斜方向发生明显变化。在瞬态阶段,负电压(SF -)线火焰的传播速率大于正电压(SF+)线火焰的传播速率,然后在发达区域两者趋于一致(准稳态传播)。这种火焰行为可分为两种:双火焰传播(状态I)和单火焰传播(状态II)。根据S和VDC的不同,每个体系可分为三个子体系。对于小VDC,火焰倾向于烧毁的电线,降低FSR。随着直流电的进一步增加,FSR由于离子风效应而增加,然后由于熔融PE的质量损失而降低。直流电压下FSR的这些非单调行为可以归因于熔融PE的行为,表现出滴、电喷雾和双电泳现象。当电压进一步升高时,火焰通过流光产生而熄灭,在过高的电压下发生电短路。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Effect of DC Electric Fields on Flame Spread Over Twin Electrical Wires
The effect of DC electric field on the behaviors of spreading flame over polyethylene (PE)-insulated twin electrical wires was investigated by varying the wire gap (S) and voltage (VDC). The twin flame spreads with the same flame spread rate (FSR) independently when no electric field is applied. With an applied DC electric field, the twin flame interacts such that FSR, flame width, and the leaning direction of interacting twin flames vary appreciably. The spread rate for wire flame with negative voltage (SF–) was larger than that with positive voltage (SF+) during transient period and then the two became the same in a developed region (a quasi-steady spread). Such a flame behavior could be grouped into two: twin flame spread (regime I) and single flame spread (regime II) after the extinction of SF+. Each regime could be categorized into three sub-regimes depending on S and VDC. For small VDC, the flame leaned toward the burnt wire, reducing FSR. With further increasing VDC, FSR increased due to the ionic wind effect and then decreased via the mass loss of molten PE. These non-monotonic behavior of FSR with DC voltage can be attributed the behaviors of molten PE, exhibiting dripping, electrospray, and di-electrophoresis phenomena. For further increased voltage, the flames were extinguished by streamer generation and an electrical short occurred at excessive voltages.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Numerical Simulation and Vorticity Analysis of Cavitating Flow Around a Marine Propeller Behind the Hull Wake Flow Visualization of a Simplified Vehicle Model During Flow State Change Mixing of Dry Air With Water-Liquid Flowing Through an Inverted U-Tube for Power Plant Condenser Applications A Numerical Study on the Low Limit Auto-Ignition Temperature of Syngas and Modification of Chemical Kinetic Mechanism Design and Verification of Cooling Fans for Engine Rooms of Mobile Hydraulics Vehicles
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1