{"title":"抗电晕聚酰亚胺膜泵发电机定子线圈的性能评价","authors":"J. Timperley, B. Nindra, S. A. Filliben","doi":"10.1109/EEIC.2005.1566256","DOIUrl":null,"url":null,"abstract":"A 69 MVA pump-generator with corona resistant filled polyimide film applied as stator coil strand insulation has been returned to service. Design modifications were implemented to take advantage of the new insulation system; testing results of these unique 13 kV stator coils are discussed. Operation data from the rewound machine is presented. This is a companion paper to \"Application of Corona Resistant Polyimide Film to Pump Generator Stator Coils\" presented at ISEI 2004","PeriodicalId":267510,"journal":{"name":"Proceedings Electrical Insulation Conference and Electrical Manufacturing Expo, 2005.","volume":"28 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1900-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Performance evaluation of pump generator stator coils with corona resistant polyimide film\",\"authors\":\"J. Timperley, B. Nindra, S. A. Filliben\",\"doi\":\"10.1109/EEIC.2005.1566256\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"A 69 MVA pump-generator with corona resistant filled polyimide film applied as stator coil strand insulation has been returned to service. Design modifications were implemented to take advantage of the new insulation system; testing results of these unique 13 kV stator coils are discussed. Operation data from the rewound machine is presented. This is a companion paper to \\\"Application of Corona Resistant Polyimide Film to Pump Generator Stator Coils\\\" presented at ISEI 2004\",\"PeriodicalId\":267510,\"journal\":{\"name\":\"Proceedings Electrical Insulation Conference and Electrical Manufacturing Expo, 2005.\",\"volume\":\"28 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1900-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Proceedings Electrical Insulation Conference and Electrical Manufacturing Expo, 2005.\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/EEIC.2005.1566256\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings Electrical Insulation Conference and Electrical Manufacturing Expo, 2005.","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/EEIC.2005.1566256","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Performance evaluation of pump generator stator coils with corona resistant polyimide film
A 69 MVA pump-generator with corona resistant filled polyimide film applied as stator coil strand insulation has been returned to service. Design modifications were implemented to take advantage of the new insulation system; testing results of these unique 13 kV stator coils are discussed. Operation data from the rewound machine is presented. This is a companion paper to "Application of Corona Resistant Polyimide Film to Pump Generator Stator Coils" presented at ISEI 2004