采用适当的正交分解法实时确定临界跨度

Jie-Jyun Wan, Joe-Air Jiang, Chia-Pang Chen, P. Chang, Hsin I. Ku, Hsin-Kai Wang, Cheng-Long Chuang, Wen-Chi Huang
{"title":"采用适当的正交分解法实时确定临界跨度","authors":"Jie-Jyun Wan, Joe-Air Jiang, Chia-Pang Chen, P. Chang, Hsin I. Ku, Hsin-Kai Wang, Cheng-Long Chuang, Wen-Chi Huang","doi":"10.1109/ICSENST.2013.6727765","DOIUrl":null,"url":null,"abstract":"In a power delivery system, excessive loads may lead to high temperature of power transmission lines. The extent of aging is proportional to the severity of the thermal overload. How to evaluate aging is an important issue for electric power systems. A critical span refers to a span where the highest conductor temperature occurs in transmission lines and thereby limits how much power can be delivered. In order to monitor real-time temperature of an overhead transmission network, this paper develops a method to simulate a dynamic model for conductor temperature distribution of transmission lines. Proper orthogonal decomposition (POD) is a widely used technique to simulate a spatio-temporal model. For high-dimensional data, POD is an efficient method to reduce the complexity of modeling. Furthermore, an extension of POD - the gappy POD - is used in this study to determine the critical spans so as to reconstruct the conductor temperature distributions of all spans. The simulation results show that the proposed method provides an efficient way of estimating transmission conductor temperature with high accuracy. The average mean square error is less than 10-4. Through building a transmission conductor temperature model, the critical span of transmission lines are determined so that effective management and scheduling in real time for power delivery systems can be achieved.","PeriodicalId":374655,"journal":{"name":"2013 Seventh International Conference on Sensing Technology (ICST)","volume":"49 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2013-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"5","resultStr":"{\"title\":\"Determination of critical span in real time using proper orthogonal decomposition\",\"authors\":\"Jie-Jyun Wan, Joe-Air Jiang, Chia-Pang Chen, P. Chang, Hsin I. Ku, Hsin-Kai Wang, Cheng-Long Chuang, Wen-Chi Huang\",\"doi\":\"10.1109/ICSENST.2013.6727765\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"In a power delivery system, excessive loads may lead to high temperature of power transmission lines. The extent of aging is proportional to the severity of the thermal overload. How to evaluate aging is an important issue for electric power systems. A critical span refers to a span where the highest conductor temperature occurs in transmission lines and thereby limits how much power can be delivered. In order to monitor real-time temperature of an overhead transmission network, this paper develops a method to simulate a dynamic model for conductor temperature distribution of transmission lines. Proper orthogonal decomposition (POD) is a widely used technique to simulate a spatio-temporal model. For high-dimensional data, POD is an efficient method to reduce the complexity of modeling. Furthermore, an extension of POD - the gappy POD - is used in this study to determine the critical spans so as to reconstruct the conductor temperature distributions of all spans. The simulation results show that the proposed method provides an efficient way of estimating transmission conductor temperature with high accuracy. The average mean square error is less than 10-4. Through building a transmission conductor temperature model, the critical span of transmission lines are determined so that effective management and scheduling in real time for power delivery systems can be achieved.\",\"PeriodicalId\":374655,\"journal\":{\"name\":\"2013 Seventh International Conference on Sensing Technology (ICST)\",\"volume\":\"49 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2013-12-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"5\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2013 Seventh International Conference on Sensing Technology (ICST)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICSENST.2013.6727765\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2013 Seventh International Conference on Sensing Technology (ICST)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICSENST.2013.6727765","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 5

摘要

在电力输送系统中,负荷过大会导致输电线路温度过高。老化的程度与热过载的严重程度成正比。如何对电力系统进行老化评估是一个重要的问题。临界跨距是指输电线路中导体温度最高的跨距,从而限制了可以输送的功率。为了实时监测架空输电网络的温度,本文提出了一种模拟输电线路导线温度分布动态模型的方法。适当正交分解(POD)是一种广泛应用于时空模型模拟的技术。对于高维数据,POD是一种降低建模复杂度的有效方法。此外,本研究还采用了微分方程的扩展——间隙微分方程(gappy POD)来确定临界跨度,从而重建各跨度的导体温度分布。仿真结果表明,该方法提供了一种有效的、高精度的传输导体温度估计方法。平均均方误差小于10-4。通过建立输电导线温度模型,确定输电线路的临界跨度,实现对输电系统的有效实时管理和调度。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Determination of critical span in real time using proper orthogonal decomposition
In a power delivery system, excessive loads may lead to high temperature of power transmission lines. The extent of aging is proportional to the severity of the thermal overload. How to evaluate aging is an important issue for electric power systems. A critical span refers to a span where the highest conductor temperature occurs in transmission lines and thereby limits how much power can be delivered. In order to monitor real-time temperature of an overhead transmission network, this paper develops a method to simulate a dynamic model for conductor temperature distribution of transmission lines. Proper orthogonal decomposition (POD) is a widely used technique to simulate a spatio-temporal model. For high-dimensional data, POD is an efficient method to reduce the complexity of modeling. Furthermore, an extension of POD - the gappy POD - is used in this study to determine the critical spans so as to reconstruct the conductor temperature distributions of all spans. The simulation results show that the proposed method provides an efficient way of estimating transmission conductor temperature with high accuracy. The average mean square error is less than 10-4. Through building a transmission conductor temperature model, the critical span of transmission lines are determined so that effective management and scheduling in real time for power delivery systems can be achieved.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Tuning the bias sensing layer: A new way to greatly improve Metal-Oxide gas sensors selectivity ZigBee based wireless sensor networks and their use in medical and health care domain Ultrasonic range measurements on the human body Wireless underground sensor network design for irrigation control: Simulation of RFID deployment An ultralow-noise Ag/AgCl electric field sensor with good stability for marine EM applications
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1