{"title":"负载变频电池储能系统","authors":"Umesh Sen, Narendra Kumar","doi":"10.1109/ICPCES.2014.7062807","DOIUrl":null,"url":null,"abstract":"This paper highlights the Control performance analysis of two area-interconnected thermal systems with and without considering battery energy storage (BES) system while subjected to 1 percentage step load disturbance. The model's two area-interconnected systems are simulated through Matlab's Simulink software. Study has been carried out by considering optimization of integral controller by Integral Square Error (ISE) method. Study results revealed that BES improves the dynamic performance of two area interconnected power systems.","PeriodicalId":337074,"journal":{"name":"2014 International Conference on Power, Control and Embedded Systems (ICPCES)","volume":"13 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2014-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"5","resultStr":"{\"title\":\"Load frequency control with battery energy storage system\",\"authors\":\"Umesh Sen, Narendra Kumar\",\"doi\":\"10.1109/ICPCES.2014.7062807\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper highlights the Control performance analysis of two area-interconnected thermal systems with and without considering battery energy storage (BES) system while subjected to 1 percentage step load disturbance. The model's two area-interconnected systems are simulated through Matlab's Simulink software. Study has been carried out by considering optimization of integral controller by Integral Square Error (ISE) method. Study results revealed that BES improves the dynamic performance of two area interconnected power systems.\",\"PeriodicalId\":337074,\"journal\":{\"name\":\"2014 International Conference on Power, Control and Embedded Systems (ICPCES)\",\"volume\":\"13 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2014-12-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"5\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2014 International Conference on Power, Control and Embedded Systems (ICPCES)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICPCES.2014.7062807\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2014 International Conference on Power, Control and Embedded Systems (ICPCES)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICPCES.2014.7062807","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Load frequency control with battery energy storage system
This paper highlights the Control performance analysis of two area-interconnected thermal systems with and without considering battery energy storage (BES) system while subjected to 1 percentage step load disturbance. The model's two area-interconnected systems are simulated through Matlab's Simulink software. Study has been carried out by considering optimization of integral controller by Integral Square Error (ISE) method. Study results revealed that BES improves the dynamic performance of two area interconnected power systems.