{"title":"通过一种设计方法-渐进式设计方法优化混合风力发电场","authors":"Y. Zhou, Priyesh Kumar, P. Bauer, J. Ferreira","doi":"10.1109/IPEMC.2009.5157547","DOIUrl":null,"url":null,"abstract":"A hybrid wind park concept which contains both constant speed wind turbine and variable speed wind turbine is proposed in this paper, as it can provide similar power quality and similar low voltage ride through capability with relatively low investment. The objective is to optimize the configuration of a hybrid wind park which has low levelised production cost, high power quality, high reliability and high low voltage ride through capability. This multi-criteria multi-objective optimization problem is solved by a design approach “Progressive Design Methodology”, which is divided into three stages. The final solution has the lowest levelised production cost with acceptable flicker level and LVRT capability.","PeriodicalId":375971,"journal":{"name":"2009 IEEE 6th International Power Electronics and Motion Control Conference","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2009-05-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"11","resultStr":"{\"title\":\"Optimization of a hybrid wind park through a design approach - Progressive Design Methodology\",\"authors\":\"Y. Zhou, Priyesh Kumar, P. Bauer, J. Ferreira\",\"doi\":\"10.1109/IPEMC.2009.5157547\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"A hybrid wind park concept which contains both constant speed wind turbine and variable speed wind turbine is proposed in this paper, as it can provide similar power quality and similar low voltage ride through capability with relatively low investment. The objective is to optimize the configuration of a hybrid wind park which has low levelised production cost, high power quality, high reliability and high low voltage ride through capability. This multi-criteria multi-objective optimization problem is solved by a design approach “Progressive Design Methodology”, which is divided into three stages. The final solution has the lowest levelised production cost with acceptable flicker level and LVRT capability.\",\"PeriodicalId\":375971,\"journal\":{\"name\":\"2009 IEEE 6th International Power Electronics and Motion Control Conference\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2009-05-17\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"11\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2009 IEEE 6th International Power Electronics and Motion Control Conference\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/IPEMC.2009.5157547\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2009 IEEE 6th International Power Electronics and Motion Control Conference","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/IPEMC.2009.5157547","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 11

摘要

本文提出了一种混合风电场概念,该概念同时包含恒速风力发电机和变速风力发电机,因为它可以以相对较低的投资提供相似的电能质量和相似的低压穿越能力。目标是优化混合风电场的配置,该风电场具有低水平生产成本、高电力质量、高可靠性和高低压穿越能力。采用渐进式设计方法求解多准则多目标优化问题,该方法分为三个阶段。最终的解决方案具有最低的平准化生产成本和可接受的闪烁水平和LVRT能力。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Optimization of a hybrid wind park through a design approach - Progressive Design Methodology
A hybrid wind park concept which contains both constant speed wind turbine and variable speed wind turbine is proposed in this paper, as it can provide similar power quality and similar low voltage ride through capability with relatively low investment. The objective is to optimize the configuration of a hybrid wind park which has low levelised production cost, high power quality, high reliability and high low voltage ride through capability. This multi-criteria multi-objective optimization problem is solved by a design approach “Progressive Design Methodology”, which is divided into three stages. The final solution has the lowest levelised production cost with acceptable flicker level and LVRT capability.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Study and implementation of a single-stage three-phase AC-DC converter A resonant gate-drive circuit capable of high-frequency and high-efficiency operation Study of multi-level rectifier in high power system based on a novel virtual flux observer Power control strategy of electronic ballast for Metal Halide Lamps Design of a digital control IC of a current source based on a three-phase controlled rectifier
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1