H. Mori, T. Niimi, M. Yoshida, M. Kondo, Y. Oshima, M. Hirako
{"title":"PSP在低压区的应用","authors":"H. Mori, T. Niimi, M. Yoshida, M. Kondo, Y. Oshima, M. Hirako","doi":"10.1109/ICIASF.2003.1274887","DOIUrl":null,"url":null,"abstract":"The PSP technique has the capability to be applied to high Knudsen number flows, such as low density gas flows, micro-flows, and so on. In this study, fundamental properties of PSPs such as sensitivity to pressure are examined especially in the range of pressure below 150 Pa (about 1 Torr), to select the most suitable PSP for the low pressure range. One of the PSP is Bath-Ru adsorbed directly on anodized aluminum, and the other PSPs are composed of porphyrin complexes bound by glassy polymer poly(TMSP). As an application of PSP to low density gas flows, we measure a pressure distribution on a surface of an aluminum plate interacting with a low density supersonic free jet. The clear two-dimensional pressure distribution was obtained by using PtTFPP/poly(TMSP), showing the feasibility of quantitative pressure measurement using the PSP.","PeriodicalId":166420,"journal":{"name":"20th International Congress on Instrumentation in Aerospace Simulation Facilities, 2003. ICIASF '03.","volume":"16 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2003-08-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Application of PSP in low pressure regime\",\"authors\":\"H. Mori, T. Niimi, M. Yoshida, M. Kondo, Y. Oshima, M. Hirako\",\"doi\":\"10.1109/ICIASF.2003.1274887\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The PSP technique has the capability to be applied to high Knudsen number flows, such as low density gas flows, micro-flows, and so on. In this study, fundamental properties of PSPs such as sensitivity to pressure are examined especially in the range of pressure below 150 Pa (about 1 Torr), to select the most suitable PSP for the low pressure range. One of the PSP is Bath-Ru adsorbed directly on anodized aluminum, and the other PSPs are composed of porphyrin complexes bound by glassy polymer poly(TMSP). As an application of PSP to low density gas flows, we measure a pressure distribution on a surface of an aluminum plate interacting with a low density supersonic free jet. The clear two-dimensional pressure distribution was obtained by using PtTFPP/poly(TMSP), showing the feasibility of quantitative pressure measurement using the PSP.\",\"PeriodicalId\":166420,\"journal\":{\"name\":\"20th International Congress on Instrumentation in Aerospace Simulation Facilities, 2003. ICIASF '03.\",\"volume\":\"16 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2003-08-25\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"20th International Congress on Instrumentation in Aerospace Simulation Facilities, 2003. ICIASF '03.\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICIASF.2003.1274887\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"20th International Congress on Instrumentation in Aerospace Simulation Facilities, 2003. ICIASF '03.","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICIASF.2003.1274887","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

摘要

PSP技术有能力应用于高克努森数流,如低密度气体流、微流等。在本研究中,研究了PSP的基本特性,如对压力的敏感性,特别是在压力低于150 Pa(约1 Torr)的范围内,以选择最适合低压范围的PSP。其中一种PSP是直接吸附在阳极氧化铝上的Bath-Ru,另一种PSP是由玻璃状聚合物聚合物(TMSP)结合的卟啉配合物组成的。作为PSP在低密度气体流动中的应用,我们测量了与低密度超音速自由射流相互作用的铝板表面的压力分布。利用PtTFPP/poly(TMSP)获得了清晰的二维压力分布,表明了利用PSP进行定量压力测量的可行性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Application of PSP in low pressure regime
The PSP technique has the capability to be applied to high Knudsen number flows, such as low density gas flows, micro-flows, and so on. In this study, fundamental properties of PSPs such as sensitivity to pressure are examined especially in the range of pressure below 150 Pa (about 1 Torr), to select the most suitable PSP for the low pressure range. One of the PSP is Bath-Ru adsorbed directly on anodized aluminum, and the other PSPs are composed of porphyrin complexes bound by glassy polymer poly(TMSP). As an application of PSP to low density gas flows, we measure a pressure distribution on a surface of an aluminum plate interacting with a low density supersonic free jet. The clear two-dimensional pressure distribution was obtained by using PtTFPP/poly(TMSP), showing the feasibility of quantitative pressure measurement using the PSP.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Flow velocity measurements in nitrogen plumes stimulated by REMPI A PIV study on the effect of pulsed-jet injection upstream of a Mach 2 shock wave/turbulent boundary layer interaction A new optical measurement method for local wall shear stress and its signal processing techniques Analyses of flow field structures around linear-type aerospike nozzles using LIF and PSP Surface pressure distribution imaging at frame rates over 1 kHz using porous pressure-sensitive paint
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1