{"title":"超高压线路鲁棒故障检测机制的设计与实现","authors":"S. Hareesh, P. Raja, M. P. Selvan","doi":"10.1109/ICPEICES.2016.7853200","DOIUrl":null,"url":null,"abstract":"This paper presents a robust fault detection mechanism in EHV lines by using Wavelet transform and FFT analysis. db6 is chosen as mother wavelet since it is best one to analyze the transients during faults and load switching. The simulated results are validated with the experimental results. For fault detection 2nd harmonic spectral component and energy difference of the consecutive windows are used as deciding parameters for fault detection. The algorithm is robust such that it won't issue trip signal for the load changes. But in the case of any fault in the system (LG fault in this paper) both second harmonic and difference of energy of consecutive windows exceeds threshold value and issues trip signal. The status of the transmission network is monitored in a mobile application developed for android.","PeriodicalId":305942,"journal":{"name":"2016 IEEE 1st International Conference on Power Electronics, Intelligent Control and Energy Systems (ICPEICES)","volume":"62 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2016-07-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Design and implementation of a robust fault detection mechanism for EHV lines\",\"authors\":\"S. Hareesh, P. Raja, M. P. Selvan\",\"doi\":\"10.1109/ICPEICES.2016.7853200\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper presents a robust fault detection mechanism in EHV lines by using Wavelet transform and FFT analysis. db6 is chosen as mother wavelet since it is best one to analyze the transients during faults and load switching. The simulated results are validated with the experimental results. For fault detection 2nd harmonic spectral component and energy difference of the consecutive windows are used as deciding parameters for fault detection. The algorithm is robust such that it won't issue trip signal for the load changes. But in the case of any fault in the system (LG fault in this paper) both second harmonic and difference of energy of consecutive windows exceeds threshold value and issues trip signal. The status of the transmission network is monitored in a mobile application developed for android.\",\"PeriodicalId\":305942,\"journal\":{\"name\":\"2016 IEEE 1st International Conference on Power Electronics, Intelligent Control and Energy Systems (ICPEICES)\",\"volume\":\"62 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2016-07-04\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2016 IEEE 1st International Conference on Power Electronics, Intelligent Control and Energy Systems (ICPEICES)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICPEICES.2016.7853200\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2016 IEEE 1st International Conference on Power Electronics, Intelligent Control and Energy Systems (ICPEICES)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICPEICES.2016.7853200","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

摘要

本文提出了一种基于小波变换和FFT分析的超高压线路鲁棒故障检测机制。选择Db6作为母小波,因为它是分析故障和负荷切换过程中暂态的最佳小波。仿真结果与实验结果相吻合。在故障检测中,采用连续窗口的二次谐波谱分量和能量差作为故障检测的决定参数。该算法具有鲁棒性,不会因负载变化而发出脱扣信号。但在系统发生故障时(本文为LG故障),连续窗口的二次谐波和能量差均超过阈值,发出跳闸信号。在为android开发的移动应用程序中监控传输网络的状态。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Design and implementation of a robust fault detection mechanism for EHV lines
This paper presents a robust fault detection mechanism in EHV lines by using Wavelet transform and FFT analysis. db6 is chosen as mother wavelet since it is best one to analyze the transients during faults and load switching. The simulated results are validated with the experimental results. For fault detection 2nd harmonic spectral component and energy difference of the consecutive windows are used as deciding parameters for fault detection. The algorithm is robust such that it won't issue trip signal for the load changes. But in the case of any fault in the system (LG fault in this paper) both second harmonic and difference of energy of consecutive windows exceeds threshold value and issues trip signal. The status of the transmission network is monitored in a mobile application developed for android.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Renewable energy systems for generating electric power: A review A novel design of circular fractal antenna using inset line feed for multiband applications Integrated control of active front steer angle and direct yaw moment using Second Order Sliding Mode technique Voltage differencing buffered amplifier based quadrature oscillator Identification of higher order critically damped systems using relay feedback test
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1