中/低压配电变电站接地系统的可接受危险区

L. Martirano, Maristella Irti, Andrea Volo, L. D’Orazio, G. Di Felice
{"title":"中/低压配电变电站接地系统的可接受危险区","authors":"L. Martirano, Maristella Irti, Andrea Volo, L. D’Orazio, G. Di Felice","doi":"10.1109/ICPS51807.2021.9416625","DOIUrl":null,"url":null,"abstract":"The paper concerns the analysis and simulation of the behavior of the total ground potential around the grounding systems of the installation-on-pole (PTP and disconnector) and MV/LV substations in order to define and quantify the best possible safety distances in terms of “acceptable risk” around the grounding systems. The analysis was conducted by adopting the Maxwell method for the analytical simulation of the grounding systems. By the analysis of the databases of the main Italian distribution system operator, each one with over than 300,000 data about the Italian grounding systems, the paper proposes a macroscopic result to define an “acceptable risk zone” by taking into consideration a weighted average value for the fault current and a medium value for the ground resistivity.","PeriodicalId":350508,"journal":{"name":"2021 IEEE/IAS 57th Industrial and Commercial Power Systems Technical Conference (I&CPS)","volume":"63 2 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2021-04-27","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Acceptable Risk Zone for Grounding Systems in Distribution MV/ LV Substations\",\"authors\":\"L. Martirano, Maristella Irti, Andrea Volo, L. D’Orazio, G. Di Felice\",\"doi\":\"10.1109/ICPS51807.2021.9416625\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The paper concerns the analysis and simulation of the behavior of the total ground potential around the grounding systems of the installation-on-pole (PTP and disconnector) and MV/LV substations in order to define and quantify the best possible safety distances in terms of “acceptable risk” around the grounding systems. The analysis was conducted by adopting the Maxwell method for the analytical simulation of the grounding systems. By the analysis of the databases of the main Italian distribution system operator, each one with over than 300,000 data about the Italian grounding systems, the paper proposes a macroscopic result to define an “acceptable risk zone” by taking into consideration a weighted average value for the fault current and a medium value for the ground resistivity.\",\"PeriodicalId\":350508,\"journal\":{\"name\":\"2021 IEEE/IAS 57th Industrial and Commercial Power Systems Technical Conference (I&CPS)\",\"volume\":\"63 2 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2021-04-27\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2021 IEEE/IAS 57th Industrial and Commercial Power Systems Technical Conference (I&CPS)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICPS51807.2021.9416625\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2021 IEEE/IAS 57th Industrial and Commercial Power Systems Technical Conference (I&CPS)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICPS51807.2021.9416625","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

本文对极上安装(PTP和隔离器)和中压/低压变电站接地系统周围总接地电位的行为进行了分析和模拟,以便根据接地系统周围的“可接受风险”来定义和量化最佳可能安全距离。采用麦克斯韦方法对接地系统进行分析仿真。通过分析意大利主要配电系统运营商的数据库,每个数据库都有超过30万的意大利接地系统数据,本文提出了一个宏观的结果,通过考虑故障电流的加权平均值和接地电阻率的中值来定义“可接受危险区”。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Acceptable Risk Zone for Grounding Systems in Distribution MV/ LV Substations
The paper concerns the analysis and simulation of the behavior of the total ground potential around the grounding systems of the installation-on-pole (PTP and disconnector) and MV/LV substations in order to define and quantify the best possible safety distances in terms of “acceptable risk” around the grounding systems. The analysis was conducted by adopting the Maxwell method for the analytical simulation of the grounding systems. By the analysis of the databases of the main Italian distribution system operator, each one with over than 300,000 data about the Italian grounding systems, the paper proposes a macroscopic result to define an “acceptable risk zone” by taking into consideration a weighted average value for the fault current and a medium value for the ground resistivity.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Single-Phase Ferroresonance in an Ungrounded System Causing Surge Arresters Failure during the System Energization Residential Electrical Fire in Shenzhen: Data Analysis and Possible Solution Automatic Power System Restoration With Inrush Current Estimation For Industrial Facility Establishment of Low Voltage Ride-Through Curves and Stability Analysis with High Photovoltaic Penetration in Power Systems DER Control and Utility Interconnection Management of a Distributed Microgrid
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1