{"title":"通过测量验证变压器的功率损耗模型:要付出的代价","authors":"J. Keradec","doi":"10.1109/IAS.2002.1042736","DOIUrl":null,"url":null,"abstract":"Two studies related to losses in ferrite core transformers are presented. They both aim to check the accuracy of transformer equivalent circuits. First, a 3 kW-two winding transformer is used in a converter which works at 25 kHz. In order to compare the losses forecasted using electronic circuit simulation together with the transformer electrical model, to those deduced from oscilloscopic electrical power measurements a lot of experimental precautions have been taken. Because the transformer have a power efficiency of 92%, knowing the lost part of the power within 10% needs input and output powers to be acquired within 0.4%. Second, to validate the copper losses electrical representation of a smaller transformer, calorimetric measurements have been carried out. Although in both cases high performance equipment is required, the most expensive is the time required to control it. As long as measurement is not considered as an unavoidable subject of investigation, no reliable result can be expected.","PeriodicalId":202482,"journal":{"name":"Conference Record of the 2002 IEEE Industry Applications Conference. 37th IAS Annual Meeting (Cat. No.02CH37344)","volume":"314 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2002-12-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"5","resultStr":"{\"title\":\"Validating the power loss model of a transformer by measurement: the price to pay\",\"authors\":\"J. Keradec\",\"doi\":\"10.1109/IAS.2002.1042736\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Two studies related to losses in ferrite core transformers are presented. They both aim to check the accuracy of transformer equivalent circuits. First, a 3 kW-two winding transformer is used in a converter which works at 25 kHz. In order to compare the losses forecasted using electronic circuit simulation together with the transformer electrical model, to those deduced from oscilloscopic electrical power measurements a lot of experimental precautions have been taken. Because the transformer have a power efficiency of 92%, knowing the lost part of the power within 10% needs input and output powers to be acquired within 0.4%. Second, to validate the copper losses electrical representation of a smaller transformer, calorimetric measurements have been carried out. Although in both cases high performance equipment is required, the most expensive is the time required to control it. As long as measurement is not considered as an unavoidable subject of investigation, no reliable result can be expected.\",\"PeriodicalId\":202482,\"journal\":{\"name\":\"Conference Record of the 2002 IEEE Industry Applications Conference. 37th IAS Annual Meeting (Cat. No.02CH37344)\",\"volume\":\"314 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2002-12-10\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"5\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Conference Record of the 2002 IEEE Industry Applications Conference. 37th IAS Annual Meeting (Cat. No.02CH37344)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/IAS.2002.1042736\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Conference Record of the 2002 IEEE Industry Applications Conference. 37th IAS Annual Meeting (Cat. No.02CH37344)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/IAS.2002.1042736","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 5

摘要

本文介绍了铁氧体铁芯变压器损耗的两项研究。它们都旨在检查变压器等效电路的准确性。首先,在转换器中使用3kw -two绕组变压器,工作频率为25khz。为了将电子电路仿真和变压器电模型预测的损耗与示波器电功率测量所得的损耗进行比较,在实验中采取了许多注意事项。由于变压器的功率效率为92%,知道10%以内的功率损失部分,需要在0.4%以内获得输入输出功率。其次,为了验证较小变压器的铜损耗电表示,进行了量热测量。虽然在这两种情况下都需要高性能的设备,但最昂贵的是控制它所需的时间。只要测量不被认为是一个不可避免的调查课题,就不能期望得到可靠的结果。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Validating the power loss model of a transformer by measurement: the price to pay
Two studies related to losses in ferrite core transformers are presented. They both aim to check the accuracy of transformer equivalent circuits. First, a 3 kW-two winding transformer is used in a converter which works at 25 kHz. In order to compare the losses forecasted using electronic circuit simulation together with the transformer electrical model, to those deduced from oscilloscopic electrical power measurements a lot of experimental precautions have been taken. Because the transformer have a power efficiency of 92%, knowing the lost part of the power within 10% needs input and output powers to be acquired within 0.4%. Second, to validate the copper losses electrical representation of a smaller transformer, calorimetric measurements have been carried out. Although in both cases high performance equipment is required, the most expensive is the time required to control it. As long as measurement is not considered as an unavoidable subject of investigation, no reliable result can be expected.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Resonant filter applications in electronic ballast Novel method in decreasing grounding resistances of urban substations by utilizing peripheral geographical conditions Practical design considerations of a single-stage single-switch parallel PFC converter for universal voltage applications Drug delivery studies on electrostatically charged dry powder inhaler aerosols using a glass bead lung model A simple rolling mill model with linear quadratic optimal controller
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1