直流负载对串联电池内阻的影响

M. I. Wahyuddin, P. Priambodo, H. Sudibyo
{"title":"直流负载对串联电池内阻的影响","authors":"M. I. Wahyuddin, P. Priambodo, H. Sudibyo","doi":"10.1109/QIR.2017.8168465","DOIUrl":null,"url":null,"abstract":"Battery energy capacity in an application system is determined by the amount of electrical energy spent to the load and time consumption. The system reliability depends on the supply of electrical energy from the battery as the power source. The energy capacity of the battery will ensure the services provided by the unit device or equipment. As an example, the UPS system provides clean, conditioned, and continues power supply for sensitive loads such as airlines computers, data centers, communication systems, and medical support systems in hospitals, etc. Therefore, it is important to estimate the accuracy of the remaining battery capacity at any time. Generally, the UPS system provides a regulated sinusoidal output voltage with switching operation and will give power to the main applications. Some UPS inverters work by utilizing power from the battery modules. The switching operation that operated by the device, will generate high frequency ripple. Many other battery applications can be analogized as a fixed load. This means that the load does not change until the energy capacity of the battery is reduced. Both static and dynamic loads will affect the battery's internal resistance. Some literatures describe the important factor of the battery modules system performance and the degradation rate associated with battery internal resistance. This paper explores how the decreasing battery capacity using the DC current load correspond to the increasing battery internal resistance. We do some experiments on discharging battery with switching load current at 10 second measuring time. We investigate and analyze the difference effect of the battery capacity on the internal resistance battery. We conclude that on continues battery loading will decrease the battery capacity which corresponds to the increasing the internal resistance value.","PeriodicalId":225743,"journal":{"name":"2017 15th International Conference on Quality in Research (QiR) : International Symposium on Electrical and Computer Engineering","volume":"4 2 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2017-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":"{\"title\":\"Direct current load effects on series battery internal resistance\",\"authors\":\"M. I. Wahyuddin, P. Priambodo, H. Sudibyo\",\"doi\":\"10.1109/QIR.2017.8168465\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Battery energy capacity in an application system is determined by the amount of electrical energy spent to the load and time consumption. The system reliability depends on the supply of electrical energy from the battery as the power source. The energy capacity of the battery will ensure the services provided by the unit device or equipment. As an example, the UPS system provides clean, conditioned, and continues power supply for sensitive loads such as airlines computers, data centers, communication systems, and medical support systems in hospitals, etc. Therefore, it is important to estimate the accuracy of the remaining battery capacity at any time. Generally, the UPS system provides a regulated sinusoidal output voltage with switching operation and will give power to the main applications. Some UPS inverters work by utilizing power from the battery modules. The switching operation that operated by the device, will generate high frequency ripple. Many other battery applications can be analogized as a fixed load. This means that the load does not change until the energy capacity of the battery is reduced. Both static and dynamic loads will affect the battery's internal resistance. Some literatures describe the important factor of the battery modules system performance and the degradation rate associated with battery internal resistance. This paper explores how the decreasing battery capacity using the DC current load correspond to the increasing battery internal resistance. We do some experiments on discharging battery with switching load current at 10 second measuring time. We investigate and analyze the difference effect of the battery capacity on the internal resistance battery. We conclude that on continues battery loading will decrease the battery capacity which corresponds to the increasing the internal resistance value.\",\"PeriodicalId\":225743,\"journal\":{\"name\":\"2017 15th International Conference on Quality in Research (QiR) : International Symposium on Electrical and Computer Engineering\",\"volume\":\"4 2 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2017-07-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"3\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2017 15th International Conference on Quality in Research (QiR) : International Symposium on Electrical and Computer Engineering\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/QIR.2017.8168465\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2017 15th International Conference on Quality in Research (QiR) : International Symposium on Electrical and Computer Engineering","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/QIR.2017.8168465","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 3

摘要

在应用系统中,电池的能量容量是由花在负载上的电能量和所消耗的时间决定的。系统的可靠性依赖于以蓄电池为电源提供的电能。电池的能量容量将保证单元装置或设备所提供的服务。UPS系统为航空公司计算机、数据中心、通信系统、医院医疗保障系统等敏感负载提供洁净、有条件、持续的供电。因此,随时估计电池剩余容量的准确性是很重要的。一般来说,UPS系统提供一个调节正弦输出电压与开关操作,并将给主要应用供电。一些UPS逆变器利用电池模块供电。由器件操作的开关操作将产生高频纹波。许多其他电池应用可以类比为固定负载。这意味着负载不会改变,直到电池的能量容量减少。静态负载和动态负载都会影响电池的内阻。一些文献描述了电池模块系统性能的重要因素以及与电池内阻相关的劣化率。本文探讨了直流电流负载下电池容量的减小与电池内阻的增大是如何对应的。我们在10秒的测量时间内对开关负载电流的电池进行了放电实验。研究和分析了电池容量对内阻电池的差异影响。我们的结论是,持续的电池负载会降低电池容量,这与内阻值的增加相对应。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Direct current load effects on series battery internal resistance
Battery energy capacity in an application system is determined by the amount of electrical energy spent to the load and time consumption. The system reliability depends on the supply of electrical energy from the battery as the power source. The energy capacity of the battery will ensure the services provided by the unit device or equipment. As an example, the UPS system provides clean, conditioned, and continues power supply for sensitive loads such as airlines computers, data centers, communication systems, and medical support systems in hospitals, etc. Therefore, it is important to estimate the accuracy of the remaining battery capacity at any time. Generally, the UPS system provides a regulated sinusoidal output voltage with switching operation and will give power to the main applications. Some UPS inverters work by utilizing power from the battery modules. The switching operation that operated by the device, will generate high frequency ripple. Many other battery applications can be analogized as a fixed load. This means that the load does not change until the energy capacity of the battery is reduced. Both static and dynamic loads will affect the battery's internal resistance. Some literatures describe the important factor of the battery modules system performance and the degradation rate associated with battery internal resistance. This paper explores how the decreasing battery capacity using the DC current load correspond to the increasing battery internal resistance. We do some experiments on discharging battery with switching load current at 10 second measuring time. We investigate and analyze the difference effect of the battery capacity on the internal resistance battery. We conclude that on continues battery loading will decrease the battery capacity which corresponds to the increasing the internal resistance value.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Effect of anode and cathode workfunction on the operating voltage and luminance of a single emissive layer organic light emitting diode Concept development for quantification of integrated energy security Indonesian text feature extraction using gibbs sampling and mean variational inference latent dirichlet allocation Measurement of particles in oil using shear horizontal surface acoustic wave sensor Palm vein recognition by using modified of local binary pattern (LBP) for extraction feature
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1