{"title":"用于癫痫发作检测头带的脑电图记录前端电路","authors":"Yu-Jui Chen, Yu-Shan Lin, H. Chiueh","doi":"10.1109/HIC.2016.7797692","DOIUrl":null,"url":null,"abstract":"Epilepsy is a common neural disorder disease; about 1.7% of the global population has epilepsy. Most patients use antiepileptic drugs to reduce their seizures. Among them, nearly one-third of the patients are drug-resistant epilepsy. The alternative treatment is the resection surgery of removing the epileptogenic zone. However, all above patients will still have some seizures, which will influence the patients' quality-of-life, and further introduce danger and inconvenience to patients and people around. This paper presents a design and development of a frontend circuitry in EEG reading for a smart epileptic seizure detection headband. The headband will consist of a textile headband with printed-circuit-board (PCB) inside, and textiled electrodes on it. The PCB includes following circuits: an electroencephalography (EEG) recorder, an epileptic seizure detector circuit, and a Bluetooth transmitter. The analog frontend circuit of EEG recording circuits and its prototype with system integration will be present in this paper. The result of designed circuits yields a compact and low-power design for EEG recording which is suitable for wearable headband designs.","PeriodicalId":333642,"journal":{"name":"2016 IEEE Healthcare Innovation Point-Of-Care Technologies Conference (HI-POCT)","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2016-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":"{\"title\":\"EEG recording frontend circuitry for epileptic seizure detection headband\",\"authors\":\"Yu-Jui Chen, Yu-Shan Lin, H. Chiueh\",\"doi\":\"10.1109/HIC.2016.7797692\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Epilepsy is a common neural disorder disease; about 1.7% of the global population has epilepsy. Most patients use antiepileptic drugs to reduce their seizures. Among them, nearly one-third of the patients are drug-resistant epilepsy. The alternative treatment is the resection surgery of removing the epileptogenic zone. However, all above patients will still have some seizures, which will influence the patients' quality-of-life, and further introduce danger and inconvenience to patients and people around. This paper presents a design and development of a frontend circuitry in EEG reading for a smart epileptic seizure detection headband. The headband will consist of a textile headband with printed-circuit-board (PCB) inside, and textiled electrodes on it. The PCB includes following circuits: an electroencephalography (EEG) recorder, an epileptic seizure detector circuit, and a Bluetooth transmitter. The analog frontend circuit of EEG recording circuits and its prototype with system integration will be present in this paper. The result of designed circuits yields a compact and low-power design for EEG recording which is suitable for wearable headband designs.\",\"PeriodicalId\":333642,\"journal\":{\"name\":\"2016 IEEE Healthcare Innovation Point-Of-Care Technologies Conference (HI-POCT)\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2016-11-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2016 IEEE Healthcare Innovation Point-Of-Care Technologies Conference (HI-POCT)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/HIC.2016.7797692\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2016 IEEE Healthcare Innovation Point-Of-Care Technologies Conference (HI-POCT)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/HIC.2016.7797692","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
EEG recording frontend circuitry for epileptic seizure detection headband
Epilepsy is a common neural disorder disease; about 1.7% of the global population has epilepsy. Most patients use antiepileptic drugs to reduce their seizures. Among them, nearly one-third of the patients are drug-resistant epilepsy. The alternative treatment is the resection surgery of removing the epileptogenic zone. However, all above patients will still have some seizures, which will influence the patients' quality-of-life, and further introduce danger and inconvenience to patients and people around. This paper presents a design and development of a frontend circuitry in EEG reading for a smart epileptic seizure detection headband. The headband will consist of a textile headband with printed-circuit-board (PCB) inside, and textiled electrodes on it. The PCB includes following circuits: an electroencephalography (EEG) recorder, an epileptic seizure detector circuit, and a Bluetooth transmitter. The analog frontend circuit of EEG recording circuits and its prototype with system integration will be present in this paper. The result of designed circuits yields a compact and low-power design for EEG recording which is suitable for wearable headband designs.