全自动尿液分析仪测定肾小球与非肾小球血尿畸形红细胞的研究

Dias Setiawan, B. R. A. Sidharta, D. Ariningrum
{"title":"全自动尿液分析仪测定肾小球与非肾小球血尿畸形红细胞的研究","authors":"Dias Setiawan, B. R. A. Sidharta, D. Ariningrum","doi":"10.24293/ijcpml.v28i3.1927","DOIUrl":null,"url":null,"abstract":"Hematuria is a sign of glomerular and non-glomerular kidney disease. Erythrocytes that pass through the glomerulus will change shape to become dysmorphic. Dysmorphic red blood cells (dRBC) can be screened using an automatic urine analyzer based on flowcytometry to distinguish the source of hematuria from glomerular or non-glomerular. The purpose of this study was to determine the diagnostic performance of the flowcytometry-based dRBC automatic urine analyzer in differentiating glomerular and non-glomerular hematuria. This study used a cross-sectional research design at the Clinical Pathology Installation at RSUD Dr. Moewardi in Surakarta. The subjects of the study were patients with hematuria at the Polyclinic and Internal Medicine Ward, Nephrology sub-division, Pediatric Polyclinic, nephrology sub-division, Urology Surgery Polyclinic in March – July 2021. The diagnostic test was carried out after determining the cut-off value of dRBC with ROC curve and AUC value. The results showed that the cut-off value of dRBC for glomerular and non-glomerular hematuria was 67% and had the best analytical performance with sensitivity 91.07%, specificity 85.36%, AUC 0.890 (95%CI: 0.832–0.947; p=0.000). In this study, dRBC parameters can be used for screening and diagnostics of patients with glomerular and non-glomerular hematuria. Further research needs to be done with other more specific gold standards such as examination of urine sediment with a phase contrast microscope.","PeriodicalId":354500,"journal":{"name":"Indonesian Journal of Clinical Pathology and Medical Laboratory","volume":"68 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2022-09-19","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Determining Glomerular and Non-Glomerular Hematuria Dysmorphic Red Blood Cell: Study on Automatic Urine Analyzer\",\"authors\":\"Dias Setiawan, B. R. A. Sidharta, D. Ariningrum\",\"doi\":\"10.24293/ijcpml.v28i3.1927\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Hematuria is a sign of glomerular and non-glomerular kidney disease. Erythrocytes that pass through the glomerulus will change shape to become dysmorphic. Dysmorphic red blood cells (dRBC) can be screened using an automatic urine analyzer based on flowcytometry to distinguish the source of hematuria from glomerular or non-glomerular. The purpose of this study was to determine the diagnostic performance of the flowcytometry-based dRBC automatic urine analyzer in differentiating glomerular and non-glomerular hematuria. This study used a cross-sectional research design at the Clinical Pathology Installation at RSUD Dr. Moewardi in Surakarta. The subjects of the study were patients with hematuria at the Polyclinic and Internal Medicine Ward, Nephrology sub-division, Pediatric Polyclinic, nephrology sub-division, Urology Surgery Polyclinic in March – July 2021. The diagnostic test was carried out after determining the cut-off value of dRBC with ROC curve and AUC value. The results showed that the cut-off value of dRBC for glomerular and non-glomerular hematuria was 67% and had the best analytical performance with sensitivity 91.07%, specificity 85.36%, AUC 0.890 (95%CI: 0.832–0.947; p=0.000). In this study, dRBC parameters can be used for screening and diagnostics of patients with glomerular and non-glomerular hematuria. Further research needs to be done with other more specific gold standards such as examination of urine sediment with a phase contrast microscope.\",\"PeriodicalId\":354500,\"journal\":{\"name\":\"Indonesian Journal of Clinical Pathology and Medical Laboratory\",\"volume\":\"68 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2022-09-19\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Indonesian Journal of Clinical Pathology and Medical Laboratory\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.24293/ijcpml.v28i3.1927\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Indonesian Journal of Clinical Pathology and Medical Laboratory","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.24293/ijcpml.v28i3.1927","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

血尿是肾小球性和非肾小球性肾脏疾病的标志。通过肾小球的红细胞会改变形状,变得畸形。畸形红细胞(dRBC)可以使用基于流式细胞术的自动尿液分析仪进行筛选,以区分肾小球或非肾小球血尿的来源。本研究的目的是确定基于流式细胞术的dRBC自动尿液分析仪在鉴别肾小球性和非肾小球性血尿中的诊断性能。本研究采用了位于雅加达的RSUD Dr. Moewardi临床病理装置的横断面研究设计。研究对象为2021年3月至7月在该综合诊所、内科病房、肾脏病科、儿科综合诊所、肾脏病科、泌尿外科综合诊所就诊的血尿患者。用ROC曲线和AUC值确定dRBC的截止值后进行诊断试验。结果显示,dRBC对肾小球和非肾小球血尿的临界值为67%,灵敏度为91.07%,特异性为85.36%,AUC为0.890 (95%CI: 0.832 ~ 0.947;p = 0.000)。在本研究中,dRBC参数可用于肾小球性和非肾小球性血尿患者的筛查和诊断。进一步的研究需要用其他更具体的金标准来完成,比如用相衬显微镜检查尿液沉积物。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Determining Glomerular and Non-Glomerular Hematuria Dysmorphic Red Blood Cell: Study on Automatic Urine Analyzer
Hematuria is a sign of glomerular and non-glomerular kidney disease. Erythrocytes that pass through the glomerulus will change shape to become dysmorphic. Dysmorphic red blood cells (dRBC) can be screened using an automatic urine analyzer based on flowcytometry to distinguish the source of hematuria from glomerular or non-glomerular. The purpose of this study was to determine the diagnostic performance of the flowcytometry-based dRBC automatic urine analyzer in differentiating glomerular and non-glomerular hematuria. This study used a cross-sectional research design at the Clinical Pathology Installation at RSUD Dr. Moewardi in Surakarta. The subjects of the study were patients with hematuria at the Polyclinic and Internal Medicine Ward, Nephrology sub-division, Pediatric Polyclinic, nephrology sub-division, Urology Surgery Polyclinic in March – July 2021. The diagnostic test was carried out after determining the cut-off value of dRBC with ROC curve and AUC value. The results showed that the cut-off value of dRBC for glomerular and non-glomerular hematuria was 67% and had the best analytical performance with sensitivity 91.07%, specificity 85.36%, AUC 0.890 (95%CI: 0.832–0.947; p=0.000). In this study, dRBC parameters can be used for screening and diagnostics of patients with glomerular and non-glomerular hematuria. Further research needs to be done with other more specific gold standards such as examination of urine sediment with a phase contrast microscope.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Comparison of Lateral-flow Nanoparticle Fluorescence Assay and ELISA Method for Interferon-y Release Assay Test Correlation between VCAM-1 Level and Absolute Monocyte Count in Coronary Artery Disease Performance Evaluation of Semi-quantitative Urine Albumin Creatinine Ratio Using Meditape UC-11A Strip Test Risk Factors of Fungal Growth in Sputum Culture from Severe and Critical COVID-19 Patients Analysis of Albumin to Globulin Ratio as A Prognostic Predictor in Lupus Nephritis Patients
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1