R. Garaev, A. Tyazhev, O. Tolbanov, A. Zarubin, D. Mokeev
{"title":"基于砷化镓、铬补偿、x射线暴露探测器的灵敏度和脉冲特性研究","authors":"R. Garaev, A. Tyazhev, O. Tolbanov, A. Zarubin, D. Mokeev","doi":"10.1109/SIBCON.2011.6074982","DOIUrl":null,"url":null,"abstract":"This paper presents the results of experimental investigations of sensitivity and pulse characteristics of detectors based on gallium arsenide compensated with chromium exposure to X-ray band 60–120 keV. A comparison of the sensitivity of detectors based on different materials has been made.","PeriodicalId":169606,"journal":{"name":"2011 International Siberian Conference on Control and Communications (SIBCON)","volume":"24 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2011-11-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Investigation of sensitivity and pulse characteristics of detectors based on GaAs, compensated with chromium, exposed to X-ray\",\"authors\":\"R. Garaev, A. Tyazhev, O. Tolbanov, A. Zarubin, D. Mokeev\",\"doi\":\"10.1109/SIBCON.2011.6074982\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper presents the results of experimental investigations of sensitivity and pulse characteristics of detectors based on gallium arsenide compensated with chromium exposure to X-ray band 60–120 keV. A comparison of the sensitivity of detectors based on different materials has been made.\",\"PeriodicalId\":169606,\"journal\":{\"name\":\"2011 International Siberian Conference on Control and Communications (SIBCON)\",\"volume\":\"24 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2011-11-10\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2011 International Siberian Conference on Control and Communications (SIBCON)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/SIBCON.2011.6074982\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2011 International Siberian Conference on Control and Communications (SIBCON)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/SIBCON.2011.6074982","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Investigation of sensitivity and pulse characteristics of detectors based on GaAs, compensated with chromium, exposed to X-ray
This paper presents the results of experimental investigations of sensitivity and pulse characteristics of detectors based on gallium arsenide compensated with chromium exposure to X-ray band 60–120 keV. A comparison of the sensitivity of detectors based on different materials has been made.