Wang Zezhong, Lu Binxian, Li Chengrong, Xiao Baoming, Huang Cheng
{"title":"高压变电站微处理机继电器对电磁脉冲的敏感性","authors":"Wang Zezhong, Lu Binxian, Li Chengrong, Xiao Baoming, Huang Cheng","doi":"10.1109/ICSMC2.2003.1428306","DOIUrl":null,"url":null,"abstract":"Based on the transient electric field measurement in the 500 kV substations, the authors measured the EMP susceptibility of a set of microprocessor-based protection relay of high voltage substations to electromagnetic field pulse (EMP). The results of measurement show that the field suppression effect of shielding box of protection relay and the ability of relay to resist interference like as EMP are enough to be compatible in the maximal transient switching electric field in substations","PeriodicalId":272545,"journal":{"name":"2003 IEEE International Symposium on Electromagnetic Compatibility, 2003. EMC '03.","volume":"24 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2003-05-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"The susceptibility of the microprocessor-based relay of high voltage substations to EMP\",\"authors\":\"Wang Zezhong, Lu Binxian, Li Chengrong, Xiao Baoming, Huang Cheng\",\"doi\":\"10.1109/ICSMC2.2003.1428306\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Based on the transient electric field measurement in the 500 kV substations, the authors measured the EMP susceptibility of a set of microprocessor-based protection relay of high voltage substations to electromagnetic field pulse (EMP). The results of measurement show that the field suppression effect of shielding box of protection relay and the ability of relay to resist interference like as EMP are enough to be compatible in the maximal transient switching electric field in substations\",\"PeriodicalId\":272545,\"journal\":{\"name\":\"2003 IEEE International Symposium on Electromagnetic Compatibility, 2003. EMC '03.\",\"volume\":\"24 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2003-05-16\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2003 IEEE International Symposium on Electromagnetic Compatibility, 2003. EMC '03.\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICSMC2.2003.1428306\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2003 IEEE International Symposium on Electromagnetic Compatibility, 2003. EMC '03.","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICSMC2.2003.1428306","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
The susceptibility of the microprocessor-based relay of high voltage substations to EMP
Based on the transient electric field measurement in the 500 kV substations, the authors measured the EMP susceptibility of a set of microprocessor-based protection relay of high voltage substations to electromagnetic field pulse (EMP). The results of measurement show that the field suppression effect of shielding box of protection relay and the ability of relay to resist interference like as EMP are enough to be compatible in the maximal transient switching electric field in substations