M. Hayashi, H. Mochizuki, Y. Noro, T. Karube, N. Furukawa, A. Kakehi, K. Takagi
{"title":"南福光背靠背换流站自动频率控制器的验证","authors":"M. Hayashi, H. Mochizuki, Y. Noro, T. Karube, N. Furukawa, A. Kakehi, K. Takagi","doi":"10.1109/DRPT.2000.855694","DOIUrl":null,"url":null,"abstract":"A multi-variable controlled AFC (automatic frequency controller) (AFC) is installed in Minami-Fukumitsu BTB (back-to-back) to stabilize the frequency of the power system after a large disturbance (like one part of the power system is divided from the other part) and to enhance suppression of frequency fluctuation. This paper shows study results on unique problems caused by system configuration and test results using an actual power system to verify performance. It also shows the effectiveness of power system analysis.","PeriodicalId":127287,"journal":{"name":"DRPT2000. International Conference on Electric Utility Deregulation and Restructuring and Power Technologies. Proceedings (Cat. No.00EX382)","volume":"19 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2000-04-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"5","resultStr":"{\"title\":\"A verification of automatic frequency controller for Minami-Fukumitsu back-to-back converter station\",\"authors\":\"M. Hayashi, H. Mochizuki, Y. Noro, T. Karube, N. Furukawa, A. Kakehi, K. Takagi\",\"doi\":\"10.1109/DRPT.2000.855694\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"A multi-variable controlled AFC (automatic frequency controller) (AFC) is installed in Minami-Fukumitsu BTB (back-to-back) to stabilize the frequency of the power system after a large disturbance (like one part of the power system is divided from the other part) and to enhance suppression of frequency fluctuation. This paper shows study results on unique problems caused by system configuration and test results using an actual power system to verify performance. It also shows the effectiveness of power system analysis.\",\"PeriodicalId\":127287,\"journal\":{\"name\":\"DRPT2000. International Conference on Electric Utility Deregulation and Restructuring and Power Technologies. Proceedings (Cat. No.00EX382)\",\"volume\":\"19 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2000-04-04\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"5\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"DRPT2000. International Conference on Electric Utility Deregulation and Restructuring and Power Technologies. Proceedings (Cat. No.00EX382)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/DRPT.2000.855694\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"DRPT2000. International Conference on Electric Utility Deregulation and Restructuring and Power Technologies. Proceedings (Cat. No.00EX382)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/DRPT.2000.855694","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
A verification of automatic frequency controller for Minami-Fukumitsu back-to-back converter station
A multi-variable controlled AFC (automatic frequency controller) (AFC) is installed in Minami-Fukumitsu BTB (back-to-back) to stabilize the frequency of the power system after a large disturbance (like one part of the power system is divided from the other part) and to enhance suppression of frequency fluctuation. This paper shows study results on unique problems caused by system configuration and test results using an actual power system to verify performance. It also shows the effectiveness of power system analysis.