{"title":"基于自适应线路增强控制方案的并网太阳能光伏发电电能质量改善","authors":"Priyank Shah, Ikhlaq Hussain, Bhim Singh","doi":"10.1109/CERA.2017.8343389","DOIUrl":null,"url":null,"abstract":"This paper presents a control scheme based on sign least mean kurtosis (SLMK) with adaptive line enhancer for three phase grid interfaced solar photovoltaic (PV) system. The SLMK based control scheme serves manifold objectives such as load balancing, improve solar power penetration into the distributed network and power factor correction. The SLMK algorithm is used to extract weights of fundamental load current for each phase. Test results show satisfactory performance for a proposed system under steady state and dynamic conditions such as load unbalancing, variable solar insolation. The total harmonic distortions (THDs) of grid currents and voltages are found within limits of IEEE-519 and 929 standards.","PeriodicalId":286358,"journal":{"name":"2017 6th International Conference on Computer Applications In Electrical Engineering-Recent Advances (CERA)","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2017-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":"{\"title\":\"Power quality improvement of grid interfaced solar PV using adaptive line enhancer based control scheme\",\"authors\":\"Priyank Shah, Ikhlaq Hussain, Bhim Singh\",\"doi\":\"10.1109/CERA.2017.8343389\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper presents a control scheme based on sign least mean kurtosis (SLMK) with adaptive line enhancer for three phase grid interfaced solar photovoltaic (PV) system. The SLMK based control scheme serves manifold objectives such as load balancing, improve solar power penetration into the distributed network and power factor correction. The SLMK algorithm is used to extract weights of fundamental load current for each phase. Test results show satisfactory performance for a proposed system under steady state and dynamic conditions such as load unbalancing, variable solar insolation. The total harmonic distortions (THDs) of grid currents and voltages are found within limits of IEEE-519 and 929 standards.\",\"PeriodicalId\":286358,\"journal\":{\"name\":\"2017 6th International Conference on Computer Applications In Electrical Engineering-Recent Advances (CERA)\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2017-10-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2017 6th International Conference on Computer Applications In Electrical Engineering-Recent Advances (CERA)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/CERA.2017.8343389\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2017 6th International Conference on Computer Applications In Electrical Engineering-Recent Advances (CERA)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/CERA.2017.8343389","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Power quality improvement of grid interfaced solar PV using adaptive line enhancer based control scheme
This paper presents a control scheme based on sign least mean kurtosis (SLMK) with adaptive line enhancer for three phase grid interfaced solar photovoltaic (PV) system. The SLMK based control scheme serves manifold objectives such as load balancing, improve solar power penetration into the distributed network and power factor correction. The SLMK algorithm is used to extract weights of fundamental load current for each phase. Test results show satisfactory performance for a proposed system under steady state and dynamic conditions such as load unbalancing, variable solar insolation. The total harmonic distortions (THDs) of grid currents and voltages are found within limits of IEEE-519 and 929 standards.