{"title":"考虑承诺负荷的配电网潮流设计方法","authors":"S. Jamali, M. Javdan, H. Shateri, M. Ghorbani","doi":"10.1109/UPEC.2006.367602","DOIUrl":null,"url":null,"abstract":"The conventional load flow methods for transmission systems could not be utilized for distribution systems, due to their especial characteristics. If methods like Newton-Raphson and fast-decoupled are used for distribution systems, the probability of the convergence would be low. Therefore, due to inherent characteristics of distribution systems, it is essential to develop the distribution version of the load flow methods. One of the applications of distribution load flow methods is in the design process, at either MV or LV level. There are two types of loads in the design process, current committed and demand committed loads that both must be considered by load flow for design purpose. This paper presents a load flow method for distribution network design, which can handle both current and demand committed loads","PeriodicalId":184186,"journal":{"name":"Proceedings of the 41st International Universities Power Engineering Conference","volume":"46 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2006-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"24","resultStr":"{\"title\":\"Load Flow Method for Distribution Network Design by Considering Committed Loads\",\"authors\":\"S. Jamali, M. Javdan, H. Shateri, M. Ghorbani\",\"doi\":\"10.1109/UPEC.2006.367602\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The conventional load flow methods for transmission systems could not be utilized for distribution systems, due to their especial characteristics. If methods like Newton-Raphson and fast-decoupled are used for distribution systems, the probability of the convergence would be low. Therefore, due to inherent characteristics of distribution systems, it is essential to develop the distribution version of the load flow methods. One of the applications of distribution load flow methods is in the design process, at either MV or LV level. There are two types of loads in the design process, current committed and demand committed loads that both must be considered by load flow for design purpose. This paper presents a load flow method for distribution network design, which can handle both current and demand committed loads\",\"PeriodicalId\":184186,\"journal\":{\"name\":\"Proceedings of the 41st International Universities Power Engineering Conference\",\"volume\":\"46 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2006-09-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"24\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Proceedings of the 41st International Universities Power Engineering Conference\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/UPEC.2006.367602\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings of the 41st International Universities Power Engineering Conference","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/UPEC.2006.367602","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 24

摘要

传统的输电系统潮流计算方法由于其自身的特殊性,不能应用于配电系统。如果将Newton-Raphson和快速解耦等方法用于配电系统,收敛的概率会很低。因此,由于配电系统的固有特性,开发配电版的潮流方法是十分必要的。配电潮流法的一个应用是在设计过程中,在中压或低压水平。在设计过程中有两种类型的负荷,电流承诺负荷和需求承诺负荷,这两种负荷在设计时都必须考虑到。提出了一种既能处理当前负荷又能处理需求负荷的配电网潮流设计方法
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Load Flow Method for Distribution Network Design by Considering Committed Loads
The conventional load flow methods for transmission systems could not be utilized for distribution systems, due to their especial characteristics. If methods like Newton-Raphson and fast-decoupled are used for distribution systems, the probability of the convergence would be low. Therefore, due to inherent characteristics of distribution systems, it is essential to develop the distribution version of the load flow methods. One of the applications of distribution load flow methods is in the design process, at either MV or LV level. There are two types of loads in the design process, current committed and demand committed loads that both must be considered by load flow for design purpose. This paper presents a load flow method for distribution network design, which can handle both current and demand committed loads
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Transient Short-Circuit Behaviour of Distributed Energy Sources and Their Influence on Protection Coordination Using Active Power Filter Based on New Control Strategy to Compensate Power Quality Assessment of DSM Potential in the Governmental Sector in Egypt and its Effect on the National Power System Development A New Method for the Price Determination of the Reactive Power Supply Grid Integration of Wind Farms Using SVC and STATCOM
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1